Page 5
Troubleshooting
Video inverted or rolling and unstable.
• Reverse the wires of the twisted pair at either
the transmitter or receiver.
No video out at the receiver.
• Check to make sure that there is video in at
the transmit end.
• Make sure that the pair of wires you are using
is not open or shorted between the transmit
and receiver points.
• Check power to the receiver.
Ghost image at the receiver.
• Bridge tap or "T" tap on the twisted pair video
line. Remove tap.
For additional help with problems please call NITEK
®
Tech-
nical Assistance at (800) 528-4343. Hours are from 8am to
5pm Central Standard Time Monday through Friday. We are
always ready to help.
Problem
Fix/Cause
Problem
Fix/Cause
Limited Warranty
NITEK
®
warranties that this unit will be free from defects in
materials and/or workmanship. Defective units will be re-
paired or replaced at our option within 2 years from the date of
shipment. This warranty does not apply to units abused
through misuse or subjected to improper and/or excessive
voltage, beyond our control.
For complete warranty details contact NITEK
®
Problem