Nitek VH456 Installation And Operation Manual Download Page 2

Installation 

 

VH456 w/Passive (Balun) Transmitter

 

 
1)  Connect Balun to Camera - Using the installation 

manual provided with the balun connect it to the 
video source, usually a video camera. If you have a 
UTP ready camera connect the twisted pair directly 
to the camera video out. 

2)  Connect Twisted Pair to VH456 - The twisted pair 

can be connected to either the push-in terminal 
blocks or the RJ45 jack. 

3)  Connect Video Out to your System - Using standard 

coax cable connect from the video out BNC to your 
system as needed for viewing. 

4)  Set DIP Switches for Distance - Using the chart 

below set the 8 position DIP switches on the VH451 
for the distance of your tested pair line plus any coax 
on each end. The modules are numbered to match 
the connections. Knowing the distance and setting 
the switch will save you time and provide you with 
the best possible picture. Settings listed are for 
standard communication cable. Should you be using 
wire gages less than 22 awg or shielded wire with 
less than 10 pair your settings may vary. Call Nitek 
Tech Support for help. 

5)  Connect the Power Supply - Connect a 12/24 VAC/

VDC power supply to the power input terminals. 

 

VH456 w/TT560 Transmitter

 

 
1)  Connect Transmitter to Camera - Refer to the TT560 

manual for the installation of the TT560 transmitter. 

2)  Connect Twisted Pair to VH456 - The twisted pair 

can be connected to either the push-in terminal 
blocks or the RJ45 jack. 

3)  Connect Video Out to your System - Using standard 

coax cable connect from the video out BNC to your 
system as needed for viewing. 

4)  Set DIP Switches for Distance - Using the chart set 

the 8 position DIP switches on the VH456 for the 
distance of your tested pair line plus any coax on 
each end. The modules are numbered to match the 
connections. Knowing the distance and setting the 
switch will save you time and provide you with the 
best possible picture. Settings listed are for standard 
communication cable. Should you be using wire 
gages less than 22 awg or shielded wire with less 
than 10 pair your settings may vary. Call Nitek Tech 
Support for help. 

5)  Connect the Power Supply - Connect a 12/24 VAC/

VDC power supply to the power input terminals 

Unmarked positions are OFF 

Video 

Level 

Gain 

Video 

Peaking 

Switch Position 

1 2 3 4 5 6 7 8 

<500 

(150)        

 

>500 

(150)     

ON 

  

 

>1000 

(300)     

ON 

 

ON 

 

>1500 (450) 

 

 

ON  ON  ON 

 

 

 

>2000 

(600)     ON 

ON  ON 

ON 

 

Distance in 

Feet (Meters

>2500 

(750)  ON ON ON ON    ON ON 

 

>3000 

(900)  ON ON ON ON ON ON ON 

 

Switch Setting for VH456 and Balun 

Unmarked positions are OFF 

Video 

Level 

Gain 

Video 

Peaking 

Switch Position 

1 2 3 4 5 6 7 8 

<1000 

(300)         

>1000 

(300)     

ON 

   

>1500 

(450)     ON 

ON  ON    

>2000 

(600)     

ON 

   

>2500 

(750)     ON 

ON 

ON  ON  

Distance in 

Feet (Meters) 

>3000 

(900)     ON 

ON  ON 

ON  

>3500 

(1050)  ON ON ON ON    ON ON   

>4000 

(1200)  ON ON ON ON ON ON ON   

>4500 

(1350)     ON 

ON 

ON  ON  

>5000 

(1500)     ON 

ON  ON 

ON  

>5500 

(1650)  ON ON ON ON    ON ON   

>6000 

(1800)  ON ON ON ON ON ON ON   

Switch Setting for VH456 and TT560 