Typical Installation - FTS324104R00
NITEK
CH1
POWER
VIDEO/OPTO
CH2
DATA OUT
DATA IN
ALARM OUT
ALARM IN
CH1
CH2
OPTO IN / OUT
CH
1
C
H2
BACK
FRONT
Connect incoming
fiber using SC
connectors
VIDEO IN
DATA OUT
Data Connections
AUX COMM IN / OUT
DEPENDING ON SWITCH
SETTING
DATA / ALARM CH1
DATA / ALARM CH2
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Alarm Connections
Alarm
Pin
OUT +
3
OUT -
4
IN +
5
GND
6
Data CH1
RS485
RS422
RS232
Data
RS485
RS422
RS232
IN + (A)
7
1
2
IN - (B)
8
2
--
OUT + (A)
7
7
8
OUT - (B)
8
8
--
GND
6
6
6
Rear Panel Data Connections
Set Data Format with Internal Switch
Color Description
Green System
Normal
Yellow (RX) Link working, No video at TX
Red
(TX) Power on, No video into TX
(RX) Power on, No opto into RX
Power/Video/Opto LED
Color Description
Green
Data is Low / Logic 0
Red
Data is High / Logic 1 (RS422/485)
Off
Data is Tri-state / (High - RS232)
Data LED