Construction and function
Variable Message Sign
16
Fault indication:
Low voltage indication
The LED of the undervoltage indication blinks when the power
supply sinks below a special value. In addition the default report
is shown in the menu "Information".
Fault display
The LED of the fault indication blinks when the power supply is
low (lamps are switched off) or one of the lamps fails. In addition
the default report is shown in the menu "Information".
Automatic parameter adjustment:
Eco-Remote II supports an automatic parameter adjustment with the operated system from firmware
version 3.00 and higher. Is a different configuration detected when starting Eco-Remote II, select
where the configuration shall be transmitted.
[
F1
]
: Remote control
•
stores all data from the system to the remote control.
[
F2
]
: Master circuit/lamp 1
•
stores all data from the remote control to the system.
The system is ready for operation now.
NOTE!
Upon delivery the system is configured correctly but the remote control can contain different settings. Is a
different configuration detected when starting a new system for the first time, choose „F1: remote control
new" for the transmission of the right adjustments to the remote control.
Attention:
In most cases option
[
F1
]
is chosen.
[
F2
]
is only needed when a circuit board was replaced. Choosing
the wrong option can cause the loss of all settings and the function of the system!
NOTE!
If the query is repeated at every start of the system although no settings were changed, choose
master
circuit/lamp 1
new once.