8
UK
Fault
Probable Cause
Solution
The appliance is leaking
water
The appliance is not properly
levelled
Adjust the screw feet to level the appliance (if
applicable)
The discharge outlet is blocked
Clear the discharge outlet
The appliance is leaking
water
Movement of water to the drain is
obstructed
Clear the floor of the appliance (if applicable)
The water container is damaged
Call Nisbets Essentials agent or qualified
Technician
The drip tray is overflowing
Empty the drip tray (if applicable)
The appliance is
unusually loud
The safety band has not been
removed
Remove the safety band
Loose nut/screw
Check and tighten all nuts and screws
The appliance has not been
installed in a level or stable position
Check installation position and change if
necessary
The display lamp does
not light
Replace lamp
Call Nisbets Essentials agent or qualified
Technician
Technical Specifications
Model Voltage Power Current Temperature
Range
Capacity
(litres)
Refrigerant
Dimensions
H x W x D mm
Weight
(kg)
FB046
230V
50Hz
100
0.7A
2°C to 8°C
78
R600a
(35g)
850 x 600 x
595
44
FB047
230V
50Hz
105
0.8A
-10°C to
-25°C
78
R600a
(60g)
850 x 600 x
595
45
FB048
230V
50Hz
130
0.8A
2°C to 8°C
265
R600a
(75g)
1855 x 600 x
595
69
FB049
230V
50Hz
150
0.9A
-10°C to
-25°C
258
R600a
(90g)
1855 x 600 x
595
74
FB046-FB047-FB048-FB049_ML_A5_v1_20190528.indb 8
2019/5/28 11:25