10
1.
AIR SOURCE
2.
BREATHING TUBE
ASSEMBLY AND
FLOW CONTROL
DEVICES
3.
AIR SUPPLY
HOSE
4.
SUPPLY
HOSE
LENGTH
5.
MAX
NUMBER
OF SECTIONS
6.
PRESSURE
RANGE
(PSIG AIR)
Portable or
Stationary
Compressor
NV2021/
NV2016
Flow Control
Valve Assembly
NV2027
(100ft)
NV2028
(25ft)
NV2029
(50ft)
25
50
100
150
200
250
300
1
2
2
3
4
5
6
28 - 30
28 - 30
30 - 33
33 - 36
36 - 38
38 - 39
39 - 43
Low Pressure
Compressor
or Air Pump
NV2021/
NV2015
Constant Flow
Valve Assembly
NV2035
(50ft)
NV2036
(100ft)
50
100
150
200
250
300
1
1
2
2
3
3
7 - 8
8 - 9
10 - 11
11 - 12
12 - 13
14 - 15
Portable or
Stationary
Compressor
NV2021
03-501
Climate Control Tube
Assembly
NV2027 (100ft)
NV2028 (25ft)
NV2029 (50ft)
25
50
100
150
200
250
300
1
1
2
3
4
5
6
50 - 80
55 - 85
60 - 95
65 - 95
70 - 100
75 - 100
85 - 100
Portable or
Stationary
Compressor
NV2021B/
4000-01
Cold Air Tube
Assembly
NV2027 (100ft)
NV2028 (25ft)
NV2029 (50ft)
25
50
100
150
200
250
300
1
1
2
3
4
5
6
55 - 56
56 - 57
60 - 62
65 - 67
70 - 72
77 - 78
80 - 82
Portable or
Stationary
Compressor
NV2021B/
4000-20
Hot Air Tube
Assembly
NV2027 (100ft)
NV2028 (25ft)
NV2029 (50ft)
25
50
100
150
200
250
300
1
1
2
3
4
5
6
67 - 68
69 - 70
73 - 74
77 - 78
81 - 82
86 - 87
91 - 92
This table lists Air pressure ranges needed to provide the RPB® NOVA 2000 with the volume
of air that falls within the required range of 6 -15 cfm or 170 - 425 lts/min according to U.S.
government regulations.
BREATHING AIR PRESSURE TABLE
SPECIAL OR CRITICAL USERS INSTRUCTIONS
!WARNING!
Respirators must be supplied with respirable air meeting the requirements
of CGA G-7.1 Grade D or Higher Quality.
Summary of Contents for rpb NOVA 2000