USE LIMITATIONS:
1. Do
NOT
use the respirator or enter or stay in a contaminated area under the following circumstances:
• Atmosphere contains less than 19.5% oxygen
• Atmosphere contains oil aerosols if using N protection class respirator
• For protection against gases or vapors
• Contaminants or their concentrations are unknown or immediately dangerous to life or health
• Concentrations or contaminants exceed maximum use concentrations in applicable OSHA standards
or applicable government regulations or 10 times the PEL (Permissible Exposure Limit), whichever
is lower
• For sandblasting, paint-spray operations, asbestos
2. Do
NOT
modify or misuse the respirator.
3. Do
NOT
use the respirator with beards or other facial hair that interferes with direct contact between
the face and the edge of the respirator, or any other conditions that may prevent a good face-seal.
WARNING:
This respirator helps protect against certain contaminants. It may not eliminate the risk of contracting
disease or infection.
Misuse may result in sickness or death.
Materials which may come into contact with the wearer’s skin could cause allergic reactions to
susceptible individuals.
FOR MORE INFORMATION or assistance please contact with Manufacturer.
FITTING INSTRUCTIONS
Follow these instructions each time respirator is worn.
1. Hold the respirator in one hand with the nosepiece at your fingertips, allowing the headbands to hang
below your hand.
2. Press the respirator against your face with the nosepiece on the bridge of your nose.
3. Place the top band high on the back of your head. Move the bottom band over your head and position
it below your ears.
4. Using both hands, mould the nosepiece to the shape of your nose.
5. Test the fit. Cup both hands over the respirator and exhale vigorously. If air flows around your nose,
tighten the nosepiece. If air leaks around the edges, reposition the bands for better fit.
6. Fit-check the face-seal as follows:
• Place both hands over the respirator without disturbing its position.
• If the respirator is not fitted with an exhalation valve, exhale sharply.
• If the respirator is fitted with an exhalation valve, inhale sharply (a negative pressure should be felt
inside the respirator).
• If you detect air-leaks, readjust the head straps and/or the position.
WARNING:
If you cannot achieve satisfactory fit, do NOT enter the contaminated area. See your
Supervisor.
USE INSTRUCTIONS:
1. Failure to follow all instructions and limitations concerning the use of the respirator and/or failure to
wear the respirator for the whole duration of exposure to contaminants can seriously reduce the
performance characteristics of the respirator and lead to illness, injury or death.
2. Before use, the wearer must first be trained by the employer in the correct use of the respirator in
accordance with applicable safety and health standards.
3. OSHA standards including 29 CFR 1910.134(e) (5) and CSA standard Z94.4-93 require that the
wearer be fit-tested. Before occupational use of this respirator a written respiratory protection
program must be implemented meeting all the local government requirements. In the United States
employers must comply with OSHA 29 CFR 1910.134 which includes medical evaluation, training,
and fit testing.
4. Discard the respirator and replace with a new one if:
• Excessive clogging of the respirator causes breathing difficulty.
• The respirator becomes damaged.
5. Leave the contaminated area if dizziness, irritation or other distress occurs.