background image

 

 

Contents 

System description

 ............................................................. 4

 

Main unit

 ....................................................................... 4

 

Sensor unit

 .................................................................... 4

 

Alarm unit

 ...................................................................... 5

 

Peripheral equipment

 ....................................................... 5

 

Printer

 ..................................................................... 6

 

Repeater

 .................................................................. 6

 

System specification

 ........................................................... 7

 

Physical

 ........................................................................ 7

 

Power

 ........................................................................... 8

 

Measurment

 ................................................................... 8

 

Functions

 ...................................................................... 8

 

Interface

 ........................................................................ 8

 

Operation

 .......................................................................... 9

 

Sleep mode

 .................................................................... 9

 

Backlight

 ....................................................................... 9

 

Unit of the wind speed

 ...................................................... 9

 

Power drops alarm

........................................................... 9

 

Wind speed alarm level

 ................................................... 10

 

Set the wind alarm “dividing value”

 ................................... 10

 

Set the first level alarm value

 ........................................... 10

 

Set the second level alarm value

 ....................................... 11

 

Alarm

 .......................................................................... 12

 

Mute the alarm

 .............................................................. 12

 

Turn off the alarm

 .......................................................... 12

 

Gust mode

 ................................................................... 12

 

Printed time interval

 ....................................................... 13

 

Printer setting

 ............................................................... 14

 

Printed Format

 .............................................................. 15

 

The display of the second line LEDs

 .................................. 16

 

Calibration

 ...................................................................... 17

 

Summary of Contents for AM706

Page 1: ...Anemometer AM706 Operation Installation Manual Document NLT AM706C SSEN Edition V170701 EXP Software V1 3 ...

Page 2: ...Operation 9 Sleep mode 9 Backlight 9 Unit of the wind speed 9 Power drops alarm 9 Wind speed alarm level 10 Set the wind alarm dividing value 10 Set the first level alarm value 10 Set the second level alarm value 11 Alarm 12 Mute the alarm 12 Turn off the alarm 12 Gust mode 12 Printed time interval 13 Printer setting 14 Printed Format 15 The display of the second line LEDs 16 Calibration 17 ...

Page 3: ...9 Sensor unit 20 Alarm unit AM706A1 22 Installation diagram Wiring diagram 22 Alarm unit AM706A2 23 Installation diagram 23 Wiring diagram 23 System diagrams 24 Wiring diagram 25 Supplementary wiring for printer DPU 414 26 Supplementary wiring for repeater IR761 26 ...

Page 4: ...value The AM706 is consisted of 3 parts Main unit Sensor unit Alarm units Main unit The main unit AM706C receives the signal from the sensor unit and displays Relative wind direction Relative wind speed Maximum wind speed First and second level alarm settings The main unit also output the setting of the wind speed alarm to the alarm unit Sensor unit The Sensor unit AM706S includes three parts Wind...

Page 5: ...A AM706A2 is installed on the cargo deck Light source Super bright LEDs Light form rotating flash Light color red Sound source horn Sound form continues Sound decibel 110dB A Peripheral equipment Printer DPU414 print date wind speed direction and so on Repeater IR761 redisplay the wind speed direction VDR vessel data recorder record data from the main unit GPS input position signal to the main uni...

Page 6: ...ime 500 thousand bite Printed mode thermal serial dot matrix Thermal record paper CX 050B a roll of paper 30m 10 rolls group Interface 8 bite parallel RS 232C serial Printed paper content width 112 mm 89 6 mm Repeater Operating temperature 0 40 Humidity 10 90 RH Weight 1 4kg Protection IP 23 Power DC24V Consumption 2W 24V Compass safe distance 85 cm ...

Page 7: ... Main unit 20 C 70 C Sensor unit 20 C 85 C Alarm unit 20 C 70 C Humidity Main unit 10 90 relative humidity Sensor unit 10 100 relative humidity Alarm unit 10 100 relative humidity IP degree Main unit IP 22 Sensor unit IP 56 Alarm unit AM706A1 IP 54 AM706A2 IP 56 Weight Main unit 2kg Sensor unit 10 kg Alarm unit AM706A1 0 3kg AM706A2 3kg ...

Page 8: ... The accuracy of the relative wind speed 5 min 0 1m s The accuracy of the relative wind direction display accuracy 10 output accuracy 1 Min start wind speed 1 2m s Functions Alarm power drops alarm wind speed alarm Calibration wind direction can be calibrated Interface Wind sensor input NMEA0183 MWV Output to alarm unit Switching value Output to repeater IR761 NMEA0183 MWV Output to printer DPU414...

Page 9: ...ight of the main unit Unit of the wind speed Press S on the main unit to inter the wind speed unit selection then press or to select the speed unit You can choose m s km h kts Power drops alarm The main unit will sound an alarm when one of the power supplies drops off Press any key on the main unit to mute the alarm ...

Page 10: ...ind alarm dividing value Press F once on the main unit to enter the wind alarm dividing value setting dId is flashing The first line LEDs show dId then press or to set the dividing value The second line LEDs show the setting value The dividing value here after will be referred to as X Set the first level alarm value Press F twice on the main unit to enter the 1st level alarm setting AL1 is flashin...

Page 11: ...arm value Press F three times on the display to enter the 2nd level alarm setting AL2 is flashing The first line LEDs show AL2 then press or to set the value of the 2nd level alarm The second line LEDs show the setting value Setting range OFF Turn the second level alarm off X 1 60 m s Step width 1m s X 1 216 km h Step width 2km h X 1 116 knots Step width 1knots ...

Page 12: ...06A2 the alarm installed on the cargo deck are sounding and flashing Mute the alarm You can press any button on AM706C to mute the alarms After muted the alarms lights are still flashing Turn off the alarm If you want to turn the alarm off you can press F on the main unit to inter the setting mode and set the alarm value to OFF Gust mode Press F four times on the main unit to inter the gust mode M...

Page 13: ...nterval can be adjusted Press F five times on the main unit to inter the printed time interval setting mode The second line LEDs show the time interval press or to select the interval time value You can choose from OFF 15 s 30s 60 s 5min 10min 15min 30min ...

Page 14: ...ing Command Enable 6 OFF Printing 7 ON Density 8 ON 100 Dip SW 2 1 OFF Printing Columns 80 2 ON User Font Back up ON 3 ON Character Select Normal 4 ON Zero Normal 5 ON International 6 ON Character 7 ON Set 8 OFF U S A Dip SW 3 1 ON Data Length 8 bits 2 ON Parity Setting No 3 ON Parity Condition Odd 4 ON Busy Control H W Busy 5 ON Baud 6 OFF Rate 7 OFF Select 8 OFF 4800 bps ...

Page 15: ... GPS input printed format is showing as follow 1 Date month year 2 Hour minute 3 North Latitude South Latitude 4 East Longitude West Longitude 5 Wind direction 6 Wind speed Without GPS input printed format is showing as follow 1 Date month year 2 Hour minute 3 North Latitude South Latitude 4 East Longitude West Longitude 5 Wind direction 6 Wind speed ...

Page 16: ... second level alarm is off The second line LEDs show alternately the max wind speed the setting value of the first level alarm The time interval is 5 seconds 3 First level alarm is off second level alarm is on The second line LEDs show alternately the max wind speed the setting value of the second level alarm The time interval is 5 seconds 4 First level alarm is on second level alarm is on The sec...

Page 17: ...17 Calibration ...

Page 18: ...18 Installation Main unit The main unit can be table or flush mounted Table mounting Unit mm ...

Page 19: ...ocedure 1 Make a cut out 169mmx169mm in the Console 2 Remove the mounting bracket 3 Unscrew the 4 screws on the frame then remove frame 4 Put AM706C into the cut out fix the inside 4 holes with self tapping screws ST4 2 25 5 Finally put on the frame ...

Page 20: ...black O ring flat washer spring washer two nuts cotter pin The two nuts must be screwed tightly and cotter pin locked Put the wind cups at the bottom of the bracket then install as the following order flat washer spring washer two nuts cotter pin The two nuts must be screwed tightly and cotter pin locked ...

Page 21: ...nit is mounted high enough to avoid any interference from obstacle The fixed pillar pipe diameter should be 60mm and make sure the activity radius 550mm After the installation calibration must be taken Please refer to the page P14 for detail ...

Page 22: ...d with bracket supplied Installation diagram Wiring diagram ATTENTION The three lines of LIGHT COMMON SOUND will be damaged if connected to the AC220V power supply High Voltage Hazard High voltage is on LIGHT COMMON SOUND lines when alarm is connected with power ...

Page 23: ...23 Alarm unit AM706A2 AM706A2 can be installed on a console panel on the overhead or on the bulkhead with tapping screws Installation diagram Wiring diagram Unit mm ...

Page 24: ...24 System diagrams ...

Page 25: ...25 Wiring diagram ...

Page 26: ...U 414 Supplementary wiring for repeater IR761 Female RS232 of printer DPU 414 Male RS232 of printer cable Pin 3 Print A WC8 Pin 5 Print B WC9 Male RS232 of printer cable Pin 2 NMEA0183 A WC6 Pin 1 NMEA0183 B WC7 Repeater IR761 AM706C AM706C ...

Reviews: