POSEIDON 7 NEW-C3_en_Ver.1.0_33/12
Adjustment / Test
31
G
Safety valve
Pic. G1: Safety valve
The safety valve’s factory setting for opening pressure = working pr 25 to +30 bars.
Upon each service inspection the setting must be tested and, if necessary, adjusted.
When mounting, affix ball and pressure plate to the spring with lubrication.
The seat is screwed on using a 10mm socket wrench (no gasket required).
Before testing with a pressure gauge, make sure that two threads are visible behind the locknut.
Warning:
Before starting the pump, check that the test manometer valve is open. Close the valve
slowly;
pressure must never exceed 250 bars.
Pic. G2: Tool for Safety valve
6mm Allen wrench
10mm box spanner
no.: 1206754