background image

3

1)

 Options / model variants

NEPTUNE 5 SB FA 

CAUTION!
High-pressure water jets can 
be dangerous if misused. The 
jet must not be directed at 
persons, animals, live electri-
cal equipment or the cleaner 
itself.

Wear appropriate protective 
clothing and eye protection.

Do not direct the jet towards 
yourself or towards other per-
sons in order to clean clothes 
or footwear. 

During operation of the cleaner, 
recoil forces are produced at the 
gunvalve and spray lance and, 
when the spray lance is held at 
an angle, a torque is also cre-
ated. The gunvalve and spray 
lancemust therefore be held 
fi rmly in both hands.

Do not use the cleaner when 
other people without protec-
tive clothing are in the working 
area.

Check that cleaning will not 
result in dangerous substances 
(e.g. asbestos, oil) being washed 
off the object to be cleaned and 
harming the environment.

Do not clean delicate par ts 
made of rubber, fabric, etc. with 
the 0° jet.  Keep some distance 
between high pressure nozzle 
and surface in order to prevent 
the surface from damage.
Do not use the high-pressure 
hose for lifting loads.

NOTE

!

The maximum permissible work-
ing pressure and temperature 
are printed on the high-pressure 
hose.

Do not use the cleaner if the 
power cord or high-pressure 
hose is damaged.

Ensure adequate air circulation. 
Do not cover the cleaner or oper-
ate it in inadequately ventilated 
rooms!

Store the cleaner where 
it will not be exposed to 
frost  or use antifreeze 

liquid!

Never operate the cleaner with-
out water. Even brief shortages 
of water result in severe damage 
to the pump seals.

Water connection

This high pressure 

washer/cleaner is 
only allowed to be 
connected with the 
drinking water

mains, when an appropriate 
backflow preventer has been 
installed, Type BA according to 
EN 1717.  If the back flow pre-
venter hasn’t been supplied, 
one can be ordered from your 
dealer. The length of the hose 
between the backflow preventer 
and the high pressure washer 
must be at least 12 metres (min 
diameter 3/4 inch) to absorb 
possible pressure peaks. Op-
eration by suction (for example 
from a rainwater vessel) is car-
ried out without backflow pre-
venter. Contact your dealer for 
suction set recommendations.
As soon as water has flown 
through the BA valve, this water 
is not considered to be drinking 
water any more.

Operation

Keep cabinet and service door 
closed during operation.

CAUTION!
Unsuitable extension cords 
can represent a source of 
danger. Always unwind cord 
from the reels completely to 
prevent the power cord over-
heating.

Connectors and couplings of 
extension cords must be water-
tight.

Extension cords are not recom-
mended, however if necessaray 
refer to the following recommen-
dations:

Cord length
m

Cross section

up to16 A

up to 25 A

up to 20 m 
(US: 30 ft)
(US: 50 ft)
(US: 75 ft)

ø1.5mm²
14 gauge
12 gauge
10 gauge

ø2.5mm²
12 gauge
10 gauge
not recom-
mended

20 to 50 m

ø2.5mm²

ø4.0mm²

Do not damage the power cord 
(e.g. by driving over it, pulling or 
crushing it).
Disconnect the power cord by 
grasping the plug only (do not pull 
or tug the power cord).

CAUTION!

Unsuitable fuels (e.g. gasoline) 
must not be used as they can 
explode and catch fi re.

Use clean fuel only, free of mois-
ture and contamination. Contact 
your dealer for fuel source and 
type recommendations.

If the machine is to be operated at 
fuel stations or in other potentially 
hazardous areas, the machine 
may only be employed outside 
the hazard areas defi ned in the 
German  „Technical Guidelines 
for Infl ammable Fluids“ applica-
ble at the point of use due to the 
potential explosion hazard posed 
by the burner.

If the machine is to be operated 
indoors, the local building regu-
lations must be observed for the 
discharge of the exhaust fumes 
into the atmosphere. Ensure an 
adequate supply of fresh air. 

If the machine is to be con-
nected to a fl ue gas stack, then 
local building regulations must be 
observed. We will be glad to pro-
vide tips for connection systems, 
on request.

CAUTION!

Beware of hot water and 
steam discharge up to 
150

0

C when operating in 

steam stage

.

CAUTION!

Do not touch or cover the 
exhaust. Risk of burns 
and fi re.

Summary of Contents for NEPTUNE 5 SB FA

Page 1: ...NEPTUNE 5 SB FA 107140661 Operating Instructions 1 22 Betriebsanleitung 23 43...

Page 2: ...1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 30 29 28 27 26 25 24 23 22 21 20 19 18 2 NEPTUNE 5 SB FA...

Page 3: ...l tank 7 3 8 Connecting the high pressure hose 7 3 9 Connecting the water supply 7 3 10 Electrical connection 8 3 11 Antifreeze before first use 8 4 1 Connections 8 4 2 Selecting self service mode man...

Page 4: ...below freezing 0 C 32 F anti freeze should be drawn into the pump beforehand see chapter 6 Before starting the cleaner If your 3 phase cleaner was supplied without a plug have it fitted with a suitabl...

Page 5: ...her must be at least 12 metres min diameter 3 4 inch to absorb possible pressure peaks Op eration by suction for example from a rainwater vessel is car ried out without backflow pre venter Contact you...

Page 6: ...ty examination in accord ance with the Accident Preven tion Regulations for Working with Liquid Spray Jet Devices as required but at least every 12 months by an authorised inspector After all repairs...

Page 7: ...from the frame The best places to hold the ma chine are on the handle on the frame between the front wheels and the guide rollers Everyfuel burningappliance such as pressure washers depends upon a pro...

Page 8: ...ent Capacity see chapter 9 4 Technical Data 3 3 Install Crank handle for high pressure hose reel cord reel 1 Pull cap of crank in arrow direction 2 Align tabs on crank with slot in axle 3 Put crank on...

Page 9: ...d wind up the high pressure hose 3 8 2 Machines without high pressure hose reel 1 Connect the high pressure hose quick connector to the high pressure nipple located at right rear of machine above chem...

Page 10: ...f service mode the de tergent is only drawn in from detergent tank A 5 Close and lock control panel cover 6 Open coin attachment 7 Select self service or manual mode on the selector D on the circuit b...

Page 11: ...service mode Hot water HW SB ON 0 0 0 4 3 2 F D E A 2 2 1 2 K la r w s c h e S h a m p o o w s c h e A A B 2 4 3 Self service mode In self service mode the cleaner is controlled via coin attach ment 1...

Page 12: ...onsuma bles detergent fuel anti scale Top up if necessary daily or several times a day 0 0 0 3 3 2 F 4 3 2 Switching off the cleaner 1 Empty coin box 2 Open cover for control panel 3 Turn the main swi...

Page 13: ...rge up to 150 C when operating in steam stage 4 4 Manual mode 4 4 1 Cold water operation Hot water operation up to 100 C 1 Turn the main switch to posi tion cold water Control electronics accomplishes...

Page 14: ...in the illustration are only approximate data For special applications such as disinfection the exact detergent concentration has to be deter mined by using a graduated measuring container For water...

Page 15: ...s supplementary effect that cuts through dirt 5 1 5 High Water Flow or High Pressure High pressure is not always the best solution and may also damage surfaces The cleaning effect also depends upon wa...

Page 16: ...sories to clean in difficult to reach places 3 Clean fragile areas such as motors rubber at lower pressure levels to avoid damage 5 2 2 Vehicle Task Accessories Method Vehicle bodywork Standard lance...

Page 17: ...igh pressure lance Use applicable accessories Use high pressure to dislodge large amounts of incrusted dirt or grime Use lower pressure and high water volume in order to rapidly flush away loose dirt...

Page 18: ...ge 4 Slide trigger lock to the locked position 5 Remove the water supply hose from the cleaner 6 Remove power cord plug from the electrical supply 6 4 Storing the cleaner below 0 C 32 F Store the clea...

Page 19: ...Remove filter with tool and clean it Weekly After the first 50 operating hours Every six months or 500 operating hours As required 7 2 1 Water filters 7 2 2 Oil filter 7 2 3 Checking the pump oil qua...

Page 20: ...oil see chapter 7 2 4 2 Top off oil level with fresh oil if necessary Oil type see chapter 9 4 Tech nical Data 7 2 6 Flame sensor 1 Remove the sensor and clean with a soft cloth 2 Confirm that the se...

Page 21: ...tion the machine switches off To reset Turn main switch to position OFF then start again Keep trigger squeezed for longer than 3 seconds If a leak occurs in the hose and gun and causes the machine to...

Page 22: ...tction Check fuse see chapter 9 4 Technical Data Pressure too low High pressure nozzle worn out Replace nozzle Pressure regulation set to low pressure Turn the twist grip on safety control block clock...

Page 23: ...will have one 1 year coverage from date of pur chase by the end user covering parts found defective due to faulty components materials and or bad workmanship Not included in this warranty coverage ar...

Page 24: ...corresponds to the following pertinent regulations EC Machine Directive 2006 42 EC EC Low voltage Directive 2006 95 EC EC EMC Directive 2004 108 EC Applied harmonised standards EN ISO 12100 1 EN ISO...

Page 25: ...ntiStone Automatik 29 3 8 Hochdruckschlauch anschlie en 29 3 9 Wasserschlauch anschlie en 29 3 10 Elektrischer Anschluss 30 3 11 Frostschutzmittel auffangen 30 4 1 Anschl sse 30 4 2 SB Betrieb manuell...

Page 26: ...ssen Den Ausl ser nicht festbinden Transport Das Ger t ist durch seine gro en R der leicht zu transportieren Zum sicheren Transport in und auf Fahrzeugen empfehlen wir das Ger t rutsch und kippsicher...

Page 27: ...Hoch druckreiniger darf nur an einen Trinkwasseran schluss ange schlossen werden wenn eine entsprechende R ckstau sicherung des Typs BA gem EN 1717 installiert ist Wenn die R ckstausicherung nicht mit...

Page 28: ...nach der UVV Arbeiten mit Fl ssikeitsstrahlern BGV D15 bei Bedarf jedoch mindestens alle 12 Monate durch Sachkundige auf Betriebssicher heit zu pr fen An elektrischen Ger ten muss nach jeder Instandse...

Page 29: ...je nach H henlage unter schiedlich Dies ist unabh ngig vom verwendeten Brennstoff Der Hochdruckreiniger wurde im Werk sorgf ltig getestet und eingestellt um die gr tm gliche Leistung zu erzielen Das W...

Page 30: ...f r Schlauchtrommel und Kabeltrommel montieren 1 Rastkappe der Kurbel in Pfeil richtung ziehen 2 Rastnasen der Kurbel an den Aussparungen in der Achse der Schlauch Kabeltrommel ausrichten 3 Kurbel auf...

Page 31: ...ischen oder Winter Diesel l verwenden 3 7 Hochdruckschlauch anschlie en 3 7 1 Ger te mit Schlauchtrommel 1 Anschlusskupplung A des Hochdruckschlauchs auf den Nippel in der Achsenmitte stecken 2 Schlau...

Page 32: ...in einem Gef auffangen ACHTUNG 230 V 400V 220 V 440 V Bei Ger ten mit Spannungs umschaltung unbedingt darauf achten dass die korrekte Netz spannung am Ger t eingestellt ist bevor der Netzstecker in d...

Page 33: ...uf der Timerplatine einstellen 8 Reinigungszeit je M nze am Drehschalter E mit Schraubendreher einstellen einstellbar von 30 Sekunden bis 5 Minuten 9 M nzz hler F ablesen Anzeige zeigt Zahl der eingew...

Page 34: ...istole bet tigt wird 2 W a s c h p r o g r a m m m i t Wahlschalter w hlen A Shampoow sche B Klarw sche 3 Maschine durch Bet tigen der Spritzpistole starten 4 3 1 T gliche Kontrollen 1 M nzkassette le...

Page 35: ...l auch bei kurzzeitigen Arbeitsunterbre chungen einlegen HINWEIS 20 Sekunden nach dem Schlie en der Spritzpistole schaltet das Ger t automatisch ab Das Ger t kann durch Bet tigen der Spritzpistole ern...

Page 36: ...z B Desinfektion ist die angesaugte Reinigungsmittelmenge durch auslitern zu ermitteln Wasser durchsatz des Ger tes siehe Kapitel 9 4 Technische Daten Wenn Sie Reinigungsmittel zu sammen mit dem Dampf...

Page 37: ...ndere in der Landwirtschaft zum Beispiel in Schweinest llen Die beste Wirkung wird erreicht durch Einsatz von Schaum und alkalischen Reinigern Oberfl che mit Reinigungsmitt ell sung einspr hen und 30...

Page 38: ...fbringen von unten nach oben und 30 Minuten einwirken las sen 2 Schmutz mit Hochdruck und ggf entsprechendem Zubeh r entfernen An senkrechten Fl chen wieder von unten nach oben arbeiten 3 Zum Transpor...

Page 39: ...anze Tankreinigungs kopf Reinigungsmittel Intensive J25 Multi Combi Aktive Alkafoam Desinfektion DES 3000 1 Eine dicke Schaumschicht auf die trockene Oberfl che aufbringen An senkrechten Fl chen von u...

Page 40: ...Abbildung gezeigt aufrollen 3 Spr hrohr und Zubeh r in die Halterungen einlegen 4 Ger t ausschalten 5 Wasserschlauch vom Ger t trennen 6 Ger testecker aus der Steck dose ziehen 6 4 Aufbewahrung frost...

Page 41: ...ter mit einem Werkzeug herausnehmen und reinigen W chentlich Nach den ersten 50 Betriebsstunden Alle 6 Monate oder alle 500 Betriebsstunden Bei Bedarf 7 2 1 Wasserfilter reinigen 7 2 2 lfilter reinige...

Page 42: ...itel 7 2 4 beschrieben durchf hren 2 Falls erforderlich Pumpen l bei kalter Maschine nachf l len lsorte siehe Kapitel 9 4 Technische Daten 7 2 5 Brennstofftank entleeren 1 Beh lter bereitstellen der g...

Page 43: ...gem Kurzzeitbetrieb schaltet das Ger t ab Reset Haupt schalter in Stellung OFF bringen dann erneut starten Spritzpistole l n ger als 3 Sekunden gedr ckt halten Spritzpistole undicht Spritzpistole berp...

Page 44: ...Luft aus leerem Reini gungsmittelbeh lter Reinigungsmittel Dosierventil schlie en Spr hrohr von Spritzpistole abnehmen Spritzpistole bet tigen und Maschine laufen lassen bis die Luft aus dem System e...

Page 45: ...PX5 400 230 V 3 50 Hz IPX5 230 240 V 1 50Hz IPX5 Die Bauart des Ger tes entspricht fol genden einschl gigen Bestimmungen EG Maschinenrichtlinie 2006 42 EG EG Niederspannungsrichtlinie 2006 95EEG EG Ri...

Page 46: ...pa 120 Volume flow max l h 860 Volume flow QIEC l h 800 High pressure nozzle 0750 Temperature tmax hotwater C 80 Temperature tmax steam C 150 Max water inlet temperature C 40 Max water inlet pressure...

Page 47: ......

Page 48: ...2 IRELAND Nilfisk Advance 1 Stokes Place St Stephen s Green Dublin 2 Tel 35 3 12 94 38 38 ITALY Nilfisk Advance SpA Strada Comunale della Braglia 18 26862 Guardamiglio LO Tel 39 0377 41 40 46 E mail m...

Reviews: