E
Troubleshooting
SM MC 3C_ MC 4M Ver.1.0_March 2015
40
Fault
Cause
Remedy
Pressure drop
- Air in the system.
- High pressure nozzle
blocked / worn.
- Pressure control on the
spray lance is not set
correctly.
- Water inlet temperature
too high.
Vent the system by
operating the spray gun
several times at short
intervals
.If
necessarily
operate the cleaner for a
short time without the
high pressure hose
connected.
Clean / replace the high
pressure
nozzle.
Set the required working
pressure.
See technical data section
”B”.
Pressure
fluctuations
- Lack of water
- Water inlet hose is too long
or its cross-section too
small.
- Lack of water caused by
Blocked/partly blocked water
filter.
- Lack of water because
max. permissible suction
height has not been
heeded.
- Pump sucks in air
(suction mode)
Open water tap.
Use specified water inlet
Hose (Refer to Operating
Manual).
Clean the water filter in the
water
connection.
(Never work without water
filter).
See technical data section
”B”
Check that all connections
on the suction side are tight
so no air can be sucked in.
The motor does not start when
the cleaner is switched on.
- The plug is not inserted
properly, i.e. there is no
current.
- The main fuse is switched off.
Check the plug, lead and
switch.
If necessary have them
replaced by a authorized
electrician.
Switch on the main fuse.
Summary of Contents for MC 3C
Page 1: ...MC 3C MC 4M SERVICE MANUAL ...
Page 57: ...F SM MC 3C_ MC 4M Ver 1 0_March 2015 Service Repair 57 Hose Reel MC 3C XT MC 4M XT ...
Page 63: ...F SM MC 3C_ MC 4M Ver 1 0_March 2015 Service Repair 63 Torque Settings MC 3C ...
Page 64: ...F SM MC 3C_ MC 4M Ver 1 0_March 2015 Service Repair 64 Torque Settings MC 4M ...
Page 66: ...H Wiring diagrams SM MC 3C_ MC 4M Ver 1 0_March 2015 66 MC 3C MC 4M 1 106420592A ...