9

 Operating 

instructions 

EN

3.6  Stop - dismounting of high pres su re hose

Danger of scalding!

Never dismount the high pressure hose 
when the water temperature is above 
50°C.

If the machine is set aside immediately after hot water or steam operation, it should be cooled down in 
"cold water mode" at fi rst until the tem per a ture is below 50°C.
Turn the temperature control (16) to the blue fi eld for cold water and activate the spray handle until the 
tem per a ture (17) is below 50°C. 
Then turn off the water supply and stop the Honda engine by turning the start/stop button (18) to position 

O

Close the petrol cock (pos. 19). (See instructions for the Honda engine).
Now the high pressure hose can be dismounted.

3.7 Transport 

directions

For lifting by crane, use lifting straps!

When lifting the machine by forklift truck, be sure the forks extend completely under the machine to pre-
 vent tipping. When lifting by tackle/crane a sling may be wrapped around the upper frame tubes (15) for 
lifting.

Ensure that no persons are under or near the machine when lifting it.

Always fasten the machine securely during transport. 

150

130

110

90

70

50

˚C

300

265

230

195

160

125

˚F

TEMP

˚C

140

130

110

90

150

120

100

80

70

50 60

40

30

16

19

18

17

15

15

Summary of Contents for CONTRACTOR MASTER

Page 1: ...Instruction manual 1 18 Betriebsanleitung 19 36 Manual d Instructions 37 54 Gebruikershandleiding 55 72 CONTRACTOR CONTRACTOR MASTER...

Page 2: ...essure hose 5 3 1 2 Water connection 5 3 1 3 Fuel filling for boiler 5 3 1 4 Fuel filling for Honda engine 6 3 1 5 Spray handle accessories 6 3 2 Starting up procedure 7 3 3 Operation 7 3 4 Temperatur...

Page 3: ...adjustable F C 86 302 30 150 86 302 30 150 Heat rating Kcal h kW 1053 71 1053 71 Petrol engine type Honda GX340LXE Honda GX390LXE Rated output HP kW 11 8 2 13 9 6 Petrol consumption at max pressure US...

Page 4: ...pped and the spray handle secured against inad vertent use by locking the trigger with the locking device 11 Only activate the trigger by hand Never tie it up or fix it in any other way 12 Avoid damag...

Page 5: ...ng that the pressure will never exceed the working pressure by more than 25 bar At this pressure the circulation valve will automat ically switch from high pressure to circulation mode Never let the m...

Page 6: ...tated in section 1 2 Technical data Let water run through the inlet hose to remove any impurities Attach the water inlet hose to the water connection 1 If there is a risk of impurities i e running san...

Page 7: ...e must not be started before the spilled petrol has been removed If the machine is placed in a trailer any petrol spillage must be removed before restarting the machine It is forbidden to smoke while...

Page 8: ...he choke control if having been used 3 3 Operation Always hold the spray lance with both hands Always lock the spray handle when the cleaner is not in operation Activate the high pressure washer by re...

Page 9: ...re reducing valve Clockwise B high pressure Counter clockwise A low pressure The spray lance features 2 nozzles a high pressure nozzle and a low pressure nozzle High pressure operation The max working...

Page 10: ...stop the Honda engine by turning the start stop button 18 to position O Close the petrol cock pos 19 See instructions for the Honda engine Now the high pressure hose can be dismounted 3 7 Transport di...

Page 11: ...34 FROST PROTECTION If the store room is not frost free the machine should be protected with an antifreeze The frost protection is reached by following the two points above screwing the drain plug in...

Page 12: ...ction with high pressure cleaning For that purpose Nilfisk ALTO can offer you a series of products specially developed for high pressure cleaning e g Cleaning of vehicles machines etc Disinfection Deg...

Page 13: ...er at first it may be difficult for it to absorb the detergent and the result is a reduced effect of the detergent Advice no 2 When applying a detergent on large vertical surfaces i e the sides of a t...

Page 14: ...nda manual provided with the machine Please read this before starting up The throttle limit of the engine has been adjusted by Nilfisk ALTO so that the max number of revolutions corresponds to the max...

Page 15: ...nsor j Quick coupling outlet k Spray handle l Spray lance The following sensors are built into the system Flow switches e g Ensure that there is a water flow through the boiler before it can be ignite...

Page 16: ...he drain plug 3 Allow the oil to run out and clean the drain plug of impurities Screw in the plug and refill the pump with fresh oil through the oil reservoir Holds approx 1 l From Nilfisk ALTO the pu...

Page 17: ...16 2 Cover of oil reservoir 3 Oil drain plug 4 Sludge container 14 Fuel filter 34 Drain plug for coil 2 3 4 14 34...

Page 18: ...r Warning The mixture may be caustic Do not on any occasion empty the container to prevent air getting into the system 5 Let the machine rest for 20 minutes 6 Start the machine and pump the used solut...

Page 19: ...Working pressure Air in the pump Repeat venting Check that the dosing valve fluctuating 22 is completely closed Insufficient water supply from Detach the water inlet hose and check the the water work...

Page 20: ...Ort Datum der Ausstellung Anton S rensen General Manager Technical Operations EAPC D claration CE de Conformit Nilfisk ALTO Division of Nilfisk Advance A S Industrivej 1 DK 9560 Hadsund d clare ci ap...

Page 21: ...8 7 2 14 9 6 5 3 10 23 14 4 1 15 15 34 11 13 31 30 27 21 18 29 25 32 24 22 1 10 10 4 1 20 19 22 16 17 35 36...

Page 22: ...2 200 201 Fax 3 4 93 757 8020 E mail mkt es nilfisk alto com SWEDEN ALTO Sverige AB Member of Nilfisk Advance Group Aminogatan 18 Box 4029 431 04 M lndal Tel 46 31 706 73 00 Fax 46 31 706 73 40 E mail...

Reviews: