INSTRUCTIONS FOR USE
ENGLISH
9099980000 - SC500
17
11/2014
TANK EMPTYING
An automatic float shut-off system (31) turns off the vacuum system when the recovery tank (33) is full.
The vacuum system deactivation is signalled by a sudden increase in the vacuum system motor noise, and the floor is not dried.
CAUTION!
If the vacuum system turns off accidentally (for example, when the float is activated because of a sudden
machine movement), to resume the operation: turn off the vacuum system by pressing the push-button (48),
then open the cover (34) and check that the float inside the grid (31) has gone down. Then close the cover (34)
and turn on the vacuum system by pressing the push-button (48).
When the recovery tank (33) is full, empty it according to the following procedure.
Recovery tank emptying
1. Raise the brush deck by pressing the push-button (43).
2. Lift the squeegee (29) with the pedal (8).
3. Drive the machine to the appointed disposal area.
4. Turn off the machine with the push-button (42) and remove the operator key (41).
5. Empty the recovery tank (33) with the drain hose (12). Then, rinse the tank with clean water.
Washing water tank emptying
6. Perform steps 1 to 4.
7. Empty the washing water tank (21) using the level hose (13). Then, rinse the tank with clean water.
AFTER USING THE MACHINE
After working, before leaving the machine:
1. Remove the brush as shown in the relevant paragraph.
2. Remove the operator key (41).
3. Empty the tanks (21) and (33) as shown in the relevant paragraphs.
4. Perform the daily maintenance procedures (see the Maintenance chapter).
5. Store the machine in a clean and dry place, with the brush and the squeegee lifted or removed.
MACHINE LONG INACTIVITY
If the machine is not going to be used for more than 30 days, proceed as follows:
1. Perform the procedures shown in After using the machine paragraph.
2. For versions with EcoFlex™ system, empty the detergent tank (25) and clean the system with a draining cycle (see the
procedure in Maintenance chapter).
3. Close the solution tank valve (18-B).
4. Disconnect the battery connector (9).
9099980000(2)11-2015.indb 17
05/11/2015 15:58:47
https://harrissupplyind.com - To Order Parts Call 608-268-8080