background image

INSTRUCTIONS FOR USE

ENGLISH

107412885 - SC100

7

04/2015

RECOVERY TANK CLEANING

(Figure 8)

1.  Remove the tank assembly from the machine body by using handle (9).

2.  Separate the solution tank (10) from the recovery tank (13).

3.  Open the recovery tank by prying on the hooks (A) and (B).

4.  Clean with water and detergent the lower (C) and upper (D) compartments of the tank, then rinse carefully.

5.  Reassemble the components.

6.  If necessary wash the solution tank (10) with clean water.

SOLUTION FILTER CLEANING

(Figure 9)

1.  Remove the tank assembly from the machine body.

2. 

Remove the two rubber gasket (A and B), then remove the filter strainer (C). 

3.  Clean and install them on the support (D).

AIR FILTER CLEANING

(Figure 10)

1. 

Remove the cover (A), then remove the air filter (B).

2. 

Clean the filter.

3. 

Install the filter in the housing (C) and close with the cover (A).

TROUBLESHOOTING

Trouble

Possible Cause

Remedy

The machine does not work.

The power supply cable or plug is broken.

Replace the cable.

The main switch is broken.

Replace the main switch. (*)

The push button panel is broken.

Replace the push button panel. (*)

The recovery water vacuuming is 

insufficient.

The recovery tank is full.

Empty the tank.

The squeegee bars are dirty or the blades are worn 

or damaged.

Clean and check the squeegee bars.

The inspection compartment is dirty.

Clean the compartment.

The recovery vacuum hose is disconnected or dirty. Connect or clean the hose.

The air filter is dirty.

Clean the filter.

The solution flow to the brush is 

insufficient.

The solution filter is dirty.

Clean the filter.

The solution dispensers are clogged.

Clean the solution dispensers.

The squeegees leave marks on the 

floor.

There is debris under the squeegee blades.

Remove the debris.

The squeegee blades are worn, chipped or torn.

Replace the blades.

(*) 

This maintenance procedure must be performed by an authorised Nilfisk Service Center.

For further information refer to the Service Manual, available at any Nilfisk Service Center.

DISPOSAL

Have the machine scrapped by a qualified scrapper.

Before disposal the machine, remove and separate the following materials, which must be disposed of properly according to the 

Law in force:

 

Brush

 

Plastic hoses and components

 

Electrical and electronic components (*)

(*) 

Refer to the nearest Nilfisk Center especially when disposal electrical and electronic components.

107412885(1)04-2015 A.indb   7

16/09/2015   16:54:38

Summary of Contents for SC100

Page 1: ...s English Nederlands Dansk Suomi Norsk Svensk Español Ελληνικά Italiano Português Bedienungshandbuch Instructions d utilisation Instructions for use Original instructions Gebruiksaanwijzing Brugsvejledning Ohjeet käyttöä varten Bruksanvisning Användarinstruktioner Instrucciones de uso Οδηγιες χρησης Istruzioni d uso Instruções de uso ...

Page 2: ...II SC100 107412885 04 2015 1 1 9 13 14 18 3 4 5 6 16 17 12 10 20 11 25 27 2 15 8 7 28 21 22 19 23 24 26 P100890 ...

Page 3: ...107412885 SC100 III 04 2015 2 B C click D A P100881 3 A B P100882 4 click B A C D click P100883 5 A B A B P100884 ...

Page 4: ...IV SC100 107412885 04 2015 6 A E D B C P100885 7 B A C P100886 8 A D B C P100887 9 A B C D P100888 10 A B C P100889 ...

Page 5: ... MANUAL 3 GENERAL INSTRUCTIONS 3 MACHINE DESCRIPTION 4 MACHINE STRUCTURE 4 USE OPERATION 5 SOLUTION TANK FILLING 5 MACHINE START OPERATION SCRUBBING DRYING 5 MACHINE STOP OPERATION 5 VACUUM HOSE optional 5 TANK EMPTYING 5 MACHINE TRANSPORT PARKING 5 AFTER USING THE MACHINE 5 MAINTENANCE 6 SCHEDULED MAINTENANCE TABLE 6 POWER SUPPLY CABLE CHECK 6 SQUEEGEE BAR CLEANING 6 BRUSH AND BRUSH COMPARTMENT C...

Page 6: ...fication data MACHINE model PRODUCT code MACHINE serial number OTHER REFERENCE MANUALS Service Manual that can be consulted at Nilfisk Service Centers Spare Parts List supplied with the machine SPARE PARTS AND MAINTENANCE Any repair procedure must be performed by qualified personnel or by Nilfisk Service Centers Only original spare parts and accessories must be used Contact Nilfisk for service or ...

Page 7: ...r supply cable plug cannot be connected to the outlet have an outlet installed by a qualified technician according to the law in force Before connecting the power supply plug to the electrical mains check that frequency and voltage shown on the machine serial number plate match the electrical mains voltage Do not unplug the machine by pulling the supply cable To unplug grasp the plug not the cable...

Page 8: ...treets Pay attention during machine transportation when temperature is below freezing point The water in the recovery tank or in the hoses could freeze and seriously damage the machine Use brushes supplied with the machine or those specified in the Instructions for use Manual Using other brushes could reduce safety In case of machine malfunctions ensure that these are not due to lack of maintenanc...

Page 9: ...pright position 2 Turn off the machine by pressing the push button 3 3 Press the main switch 2 to 0 4 Disconnect the power supply cable plug 27 from the electrical mains and place it on the holder 26 5 Lift the squeegee bars 17 with the pedal 8 VACUUM HOSE optional Figure 3 1 Install the vacuum hose on the vacuum inlet 22 2 Connect the power supply plug 27 to the electrical mains 3 Turn on the mac...

Page 10: ...n and the blades must be in good conditions in order to get a good drying CAUTION The squeegee bars are fastened to the machine with a snap system and can be easily removed 1 Set the machine to stop position 2 Make sure that the power supply plug is disconnected from the electrical mains 3 Lower the squeegee bars 17 with the pedal 8 4 Lower the machine to reach the lower side of the cleaning deck ...

Page 11: ...he push button panel The recovery water vacuuming is insufficient The recovery tank is full Empty the tank The squeegee bars are dirty or the blades are worn or damaged Clean and check the squeegee bars The inspection compartment is dirty Clean the compartment The recovery vacuum hose is disconnected or dirty Connect or clean the hose The air filter is dirty Clean the filter The solution flow to t...

Page 12: ...H2 O Brush rotation speed 2 100 rpm Total absorbed power 0 8 kW Electrical system voltage 220 240 V 50 60 Hz Weight with empty tanks 12 kg Gross vehicle weight GVW 15 kg Shipping weight 16 kg ACCESSORIES OPTIONS In addition to the standard components the machine can be equipped with the following accessories options according to the machine specific use 107411860 Brush cyl 310 mm 12 5 Medium PPL w...

Page 13: ...et ülalnimetatud mudel on valmistatud kooskõlas järgmiste direktiivide ja normidega Tehnilise dokumentatsiooni koostab tootja Je soussigné certifie que les modèles ci dessus sont fabriqués conformément aux directives et normes suivantes Le dossier technique est rédigé par le fabricant Allekirjoittaia vakuuttaa että yllämainittu malli on tuotettu seuraavien direktiivien ja standardien mukaan Valmis...

Page 14: ...Nilfisk A S DK 2605 Broenby Banemarksvej 58 DENMARK www nilfisk com ...

Reviews: