9. Maintenance, Trouble shooting,
Service
Service may only be carried out by authorized and
qualified personnel.
CAUTION
The system must only be serviced when
there is no voltage or pressure on the sys-
tem
1.
Turn off the main switch at the control box
2.
Open a water outlet to depressurise the syste
9.1. Installation Instruction for Flow Switch
There is a dot on one of the nut surfaces on the
sensor. This is used to position the contact point of
the sensor in relation to the direction of flow of the
medium.
This marking must be located within an angle of +/-
30° perpendicular to the direction of flow, as shown in
the example.
Diagram of sensor fitted in a pipe.
Loctite 577 is used at the factory to seal the thread,
but packing yarn/packing tape can also be used.
9.2.
Components
9.2.1.
Pumps/motor
Pumps/motor are maintenance free.
9.2.2. Control system
Maintenance free
If defective: Call a service technician
9.2.3. Flow switch
Maintenance-free.
If defective, replace the flow switch.
1. Press "0" on the control pane to stop the system.
2. Remove the cover
3. Turn "rinse/foam" handle on a satellite to foam
position.
4. Activate the spray handle on the outlet hose of
the satellite so water runs out.
5. Check that the flow switch is turned the correct
way (the wire must follow direction).
6. Turn the brass screw at the bottom of the hole
until a green diode lights up.
7. Close the spray handle again and check that the
red diode lights up.
8. Mount the cover.
9.3. Preventive maintenance
Depending on usage, maintenance should be un-
dertaken by an authorised service engineer at least
once a year in order to prevent defects and failure of
operation. Authorised engineers are persons who due
to their skills and experience have sufficient knowl-
edge of the Booster Systems and are confident with
the state work safety regulations, accident prevent-
ing regulations, lines and generally acknowledged
technical regulations such as DIN-norms and VDE-
provisions. For your safety, this unit has been manu-
factured according to all relevant regulations valid in
the EU and therefore it has been supplied with the
CE-marking. For further information, please refer to
the service department.
9.4. Internal cleaning of the unit
We recommend opening and cleaning the unit inside
min. once a month.
Summary of Contents for Ecolab Hybrid-P
Page 7: ......
Page 64: ......
Page 68: ...English EN 12 11 13 5 4 14 6 15 1 2 3 10 7 8 16 9 Hybrid P BW7 110008164 68 English EN ...
Page 72: ...English EN Hybrid P BF8 Serial no 149 0X XXXXXX 110007221 5 6 7 2 2 8 3 4 1 72 English EN ...
Page 76: ...English EN Inlet pipe Serial no 149 0X XXXXXX 7 3 5 2 1 6 110008287 4 110001406 76 English EN ...
Page 78: ...English EN Outlet pipe Serial no 148 0X XXXXXX 6 2 3 1 3 5 4 7 8 10 9 110008166 78 English EN ...
Page 80: ...English EN Outlet pipe Serial no 149 0X XXXXXX 7 1 2 6 3 4 5 110008351 80 English EN ...
Page 94: ...94 Français FR Español ES English EN Deutsch DE Installation 110003609 110008251 ...
Page 97: ...97 Français FR Español ES English EN Deutsch DE Mounting Pegasus P BW4 110008170 ...
Page 98: ...98 Français FR Español ES English EN Deutsch DE Mounting Hybrid BW7 110008171 ...
Page 99: ...99 Français FR Español ES English EN Deutsch DE ...
Page 100: ...100 Français FR Español ES English EN Deutsch DE Layout Pegasus Pegasus P BW4 ...
Page 102: ...102 Français FR Español ES English EN Deutsch DE Hybrid P BW7 Layout Hybrid ...
Page 104: ...104 Français FR Español ES English EN Deutsch DE Hybrid P BF4 Layout Hybrid ...
Page 106: ...106 Français FR Español ES English EN Deutsch DE Hybrid P BF8 Layout Hybrid ...