FORM NO. 56043123 - SR 1900 -
7
SECTION 3 — MAINTENANCE
WARNING!
Turn the key switch off and remove the key from the ignition switch before performing any machine maintenance.
MAINTENANCE SCHEDULE
Maintenance intervals given are for average operating conditions. Machines used in severe operational environments may require service more often.
Maintenance Item
Daily
Weekly
Monthly
Hours
Check for any coolant, hydraulic or refrigerant leaks.
Note: Refrigerant leaks can appear as dirty, oily areas around A/C
components and
fi
ttings.
X
8-12
Check the cab
fi
lter and clean or replace as necessary.
Note: The cab
fi
lter may need to be cleaned or replaced more often if the
machine is operated in dusty environments.
X
40
Clean the heater core
fi
ns and air box (heater only).
X
160
Clean the evaporator and heater core
fi
ns inside the evaporator-heater unit
(A/C only).
X
160
Clean the condenser
fi
ns (A/C only).
X
40
TO CLEAN AND REPLACE THE CAB FILTER
Refer to Figure 3-1.
Remove the four screws holding the
1.
Cab Filter Cover
, then remove the
Cab Filter Cover
and
Filter
from the machine.
Clean the
2.
Filter
using any of the following methods:
Tap the
Filter
gently on a
fl
at surface (dirty side down).
Clean the
Filter
with compressed air (100 psi max.) blown from the inside (cab side) of the
Filter
.
Soak the
Filter
in warm water for 15 minutes, rinse with clean water (40 psi max. water pressure), then air-dry (don’t use compressed air). Make sure the
Filter
is
completely dry
before reinstalling.
Reinstall the
3.
Filter
and
Cab Filter Cover
, then reinstall and tighten the four screws.
FIGURE 3-1 – Cab Filter