58
30 - Solution System
Detergent Models
Machines that have on-board detergent
mixing (EcoFlex Models) have a solution
control circuit board, detergent pump,
and detergent bottle From an enabling
standpoint, the detergent module (circuit
board) has the same prerequisite control
that a non-detergent solution solenoid has
The machine must be in motion, and the
scrub brushes be active
However, instead of battery negative
passing straight to the solution solenoid,
it passes into the detergent control board
This signal serves as an “Enable” function
for the detergent and solution outputs
Within the detergent module control board
is a micro controller that generates PWM
outputs for both the detergent pump and
the solution solenoid This is a battery-
negative PWM, and applies negative
voltage to the coils
The two duty cycles of the PWM outputs
are controlled by onboard potentiometers
The Burst of Power switch will
temporarily increase both detergent and
solution flow rates for 60 seconds.
Detergent Pump
The detergent pump is a solenoid-driven
diaphragm with one-way check valves As
the solenoid oscillates in and out, it drives
a flexible diaphragm that draws fluid in
during the retraction stroke, and drives
fluid out during the compression stroke. The
check valves allow fluid to enter only though
the inlet port, and exit only through the
outlet port
Unlike an AC solenoid that moves its
plunger the same direction regardless of the
electrical polarity, a DC solenoid changes
its direction of travel depending on the
electrical polarity of the coil This is an
important distinction because if the pump is
connected with the wrong polarity, it will not pump liquid
The solenoid plunger is actively driven in only one direction (intake), but passively returned via the return
spring (exhaust) If the wiring polarity is reversed, the solenoid plunger will be driven in the same direction
that the return spring has already pushed the plunger So the plunger will never move
BLK
BLK
BLK
PNK/WHT
VIO
PNK/BLU
VIO/WHT
PNK/BLU
VIO/RED
VIO/GRN
VIO
PNK
VIO
PNK
S1
SW, SPST KEY
S4
SW, BRUSH
P3
DETERGENT MODULE
B+
1
B-
5
SOL IN
2
SOL- OUT
3
DET- OUT
4
BRAKE+
6
RELAY, LVC
1
2
3
4
5
6
CURTIS 1228
KSI
5
BRAKE-
6
BRAKE+
14
D2
K1
RELAY, LVC
BATTERY GAUGE WITH HOURMETER
FET DRAIN
3
B-
4
L1
COIL, SOLENOID
1
2
L2
PUMP, DETERGENT
1
2
D1
36 VDC
+
-
K2
COIL, BRUSH
K1
Outlet
Inlet
Pos
Neg
Diaphragm
Solenoid