Nilfisk-Advance 128350598 ErP2017 Select Instructions For Use Manual Download Page 6

6

Original Instructions

EN

 

Nilfi sk Select

Stop

Turn off the machine and unplug. Unplug by grasping the 
plug, not by pulling on the electric cable.

Connecting hose, tube and nozzles

  1  

 

1.  Insert the hose connector into the suction inlet until it 

engages by a “click” sound. 

2.  Connect the hose handle to the tube and twist until they 

engage with a click.

3.  Connect the tube and nozzle and twist until they engage 

with a click.

4.  The tube is telescopic and can be adjusted to your 

height. 
Pull out the adjusting handle to extend the tube, and pull 
back to shorten to desired length.

Disengage

•  Disengage the nozzle from the tube by pressing the but-

ton.

•  Disengage the hose handle from the tube by pressing the 

button.

•  To remove the hose connection from the suction inlet, 

press button and disengage the hose.

Change of dust bag and fi lters 

The size and quality of the dust bag and 

 lters affect the 

machine ef

 ciency. Use of non original dust bags or non 

original 

 lters can cause restricted air 

 ow which may lead 

to machine overload. Using non-original dust bag or 

 lters 

will void the warranty.

The machine is a completely air tight construction. This en-
sures that air and dirt going into the machine, can only get 
out through the HEPA 

 lter in the end.

Changing the dust bag

  2  

 

The dust bag indicator shows when to change the dust bag. 
Always use original dust bags.
1.  Open the lid by pushing at the latch release in the direc-

tion of the arrows.

2.  Remove dust bag holder from dust compartment.
3.  Remove dust bag from holder. The dust bag can be 

closed by pulling the collar handle.

4.  Insert the new dust bag by guiding the collar into the 

tracks of the bag holder.

5.  Place the bag holder in the dust compartment. Check 

that the dust bag is correctly 

 tted into dust compartment.

Changing the pre-fi lter

  3  

 

The pre-

 lter protects the motor by absorbing micro-particles 

that the dust bag can not keep. Change the pre-

 lter with 

every fourth dust bag. The pre-

 lter is located behind the 

dust bag. Always use original 

 lters.

1.  Open the lid by pulling up at the latch release.
2.  Remove bag holder with bag from dust compartment.
3. Open pre-

 lter hatch by pulling handle.

4.  Take out the pre-

 lter.

5.  Fit the new pre-

 lter (ensure that the text is readable) and 

close the  pre-

 lter hatch.

6.  Place the bag holder in the dust compartment. Check 

that the dust bag is correctly 

 tted into dust compartment.

Changing the HEPA fi lter

  4  

 

The HEPA 

 lter cleans the exhaust air from micro parti-

cles the dust bag can not keep. The HEPA 

 lter can not be 

brushed or washed clean. Comfort and Superior models 
have a HEPA 

 lter indicator that shows when to change 

the HEPA 

 lter. For Classic models, change HEPA 

 lter for 

every 4th dust bag change. Always use original dust bags 
and 

 lters.

1.  Open the lid on the back of the machine by pulling the 

tap.

2.  Take out the HEPA 

 lter. 

3.  Insert the new HEPA 

 lter. Check that the HEPA 

 lter is 

correctly 

 tted. 

NB

: Only touch the 

 lter plastic frame

4.  Put the lid back and close by pushing the tap in. NB: As-

sure lid is fully closed.

Adjust the suction power 

All models have a 

 ve step adjustment on the carrying 

 handle.The suction power can also be adjusted on the re-
mote handle of the Superior models.

Power 
regu

                                                             

Current level is shown on the carrying handle on Superior/
Comfort models.

Battery replacement in hose  handle:

1.  Open the lid of the battery holder by 

sliding the lid towards the front of the 
hose handle.

2.  Replace the used batteries with two 

new ones, type 1.5V AAA. Make sure 
the polarity of the batteries is placed 
correct at the bracket.

3.  Slide the battery lid back until you 

hear a click.

Power regulation - 

Power regulation - 

Power regu

Current level

Summary of Contents for 128350598 ErP2017 Select

Page 1: ...107412672 d 05 2015 EN DE FR ES PT IT NL SV NO DA FI KO ET LV LT PL CS SK HU SL EL TR RU Instructions for use Select...

Page 2: ...2 Nilfisk Select 24 25 1 10 5 9 2 4 12 17 19 15 20 23 3 16 18 7 6 22 21 10 13 11 14 8...

Page 3: ...ng 53 59 Instruksjonsbok 60 66 Brugsvejledning 67 73 K ytt ohje 74 80 81 86 Kasutusjuhend 87 92 Lieto anas instrukcijas 93 99 Naudojimo instrukcija 100 105 Instrukcja obs ugi 106 112 N vod k pou it 11...

Page 4: ...Carrying handle Display symbols on carrying handle not standard on all models The dust bag is full and needs to be changed The HEPA lter needs to be changed Flashing indica tor early warning the HEPA...

Page 5: ...tion concerning use of the appliance in a safe way and understand the hazards involved Children shall be supervised to make sure that they do not play with the appliance Cleaning and user maintenance...

Page 6: ...rrectly tted into dust compartment Changing the pre filter 3 The pre lter protects the motor by absorbing micro particles that the dust bag can not keep Change the pre lter with every fourth dust bag...

Page 7: ...opened by pressing the release button downwards The lid is closed manually The different models of these vacuum cleaners can include different nozzles Trouble shooting Repair or service of electrical...

Page 8: ...The guarantee becomes void If a defect is caused by the use of non original Nil sk dust bags and lters If the identity number is removed from the vacuum clean er If the vacuum cleaner has been repaire...

Page 9: ...ning performance on hard oor A Dust re emission A Annual energy consumption in kWh annum 27 Electric cable length m 8 Insulation class IP20 Type of protection II Dust bag net lling l 2 7 Width mm 300...

Page 10: ...EMC Part 3 3 Limits Limitation of voltage changes voltage uctuations and icker in public low voltage supply systems for equipment with rated current 16 A per phase and not subject to conditional conne...

Page 11: ...165 Nilfisk Select 1 2 3...

Page 12: ...166 Nilfisk Select 4 6 7 5 8...

Page 13: ...167 Nilfisk Select 9 10 11...

Page 14: ...nil sk it JAPAN Nil sk Inc 1 6 6 Kita shinyokohama Kouhoku ku Yokohama 223 0059 Tel 81 45548 2571 Website www nil sk com MALAYSIA Nil sk Sdn Bhd Sd 33 Jalan KIP 10 Taman Perindustrian KIP Sri Damansar...

Reviews: