Troubleshooting
SM_MC_6P Ver.2.0_2021
35
E
Fault
Cause
Remedy
Pressure drop
-
Air in the system.
-
High pressure nozzle
blocked / worn.
-
Pressure control on the
spray lance is not set
correctly.
-
Detergent container empty.
-
Water inlet temperature
too high.
•
Vent the system by
operating the spray gun
several times at short
intervals .If necessarly
operate the cleaner for a
short time without the
High pressure hose
connected.
•
Clean / replace the high
pressure nozzle.
•
Set the required working
pressure.
•
Change container or close
detergent valve.
•
See technical data part
”
B
”.
Pressure
fluctuations
-
Lack of water
-
Water inlet hose is too long
or its cross
-
section too
small.
-
Lack of water caused by
blocked water filter.
-
Lack of water because
max. permissible suction
height has not been
heeded.
-
Pump sucks in air
(suction mode)
•
Open water tap.
•
Use specified water inlet
hose(Refer to user manual).
•
Clean the water filter in the
water connection.
(Never work without water
filter).
•
See technical data part
”
B
”
•
Check that the suction set
is air tight.
The motor does not start when
the cleaner is switced on.
-
The plug is not inserted
properly, i.e. there is no
current.
-
The main fuse is switced off.
•
Check the plug, lead and
switch.If necessary have them
replaced by a trained
electrician.
•
Switch on the main fuse.
General failures
Summary of Contents for 107146750
Page 1: ...MC 6P SERVICE MANUAL...
Page 28: ...28 SM_MC_6P Ver 2 0_2021 Function D Operation electrical System Datalogger connection...
Page 48: ...Wiring diagrams SM_MC_6P Ver 2 0_2021 48 H 106420544 1 ph 230V...
Page 49: ...Wiring diagrams SM_MC_6P Ver 2 0_2021 49 H 106420552 3 ph STAR w PCBA...
Page 50: ...Wiring diagrams SM_MC_6P Ver 2 0_2021 50 H 106420554 3 ph DELTA w PCBA...
Page 51: ...Wiring diagrams SM_MC_6P Ver 2 0_2021 51 H 106420556 3 ph STAR or DELTA w PCBA...
Page 52: ...Wiring diagrams SM_MC_6P Ver 2 0_2021 52 H 106420558 1 ph 230V w PCBA...
Page 53: ...Wiring diagrams SM_MC_6P Ver 2 0_2021 53 H 106420559 1 ph Model...
Page 54: ...Wiring diagrams SM_MC_6P Ver 2 0_2021 54 H 106420564 3 ph STAR DELTA...
Page 56: ...56 SM_MC_6P Ver 2 0_2021 Notes Notes...
Page 57: ...Nilfisk A S Industrivej 1 9650 Hadsund Denmark www nilfisk com...