I
f the TS100 does not work, and the LED “flickers”
or remains solidly lit:
Cover up the Sensor with a piece
of cardboard (your hand will actually create electromagnetic
interference under some conditions). Observe the IR test LED.
IR T
est LED Off:
Optical Inter
ference
IR T
est LED On or Flickering:
Electr
omagnetic Interference
EMI (Electr
omagnetic Interference)
Identify the sour
ce of the interference. The most common
sources of electromagnetic interference are listed in the
Installation Considerations section on pages 5 and 6. To elimi-
nate EMI try the following methods:
1. Move the sensor or the sensor cable away from the EMI
source or move the source of the EMI away from the sensor
or the cable.
2. Connect the Sensor’s GND terminal to true earth ground (if
this isn’t feasible use the main system unit’s GND terminal).
There are many methods for reducing interference. Which solution
is best for you depends on your situation. Contact Niles Technical
Support at 1-800-289-4434 if you require further assistance.