Date:
01/11/05
To:
All Niles Dealers and Representatives
From:
The Technical Support Department
Subject:
Status Power Requirements For Muting Volume Controls
Page 1 of 1
Since the introduction of the Automatic Muting Volume Controls, there have been some
questions regarding the wiring and power requirements of these controls. All Automatic Muting
Volume Controls include a muting relay feature, which requires the presence o f 12VDC at the
volume control location. If this voltage is not supplied to the volume control, the relay cannot
be activated and the volume control will not allow the audio signal to be routed to the
loudspeakers.
In the case of the MVC series of controls , the most convenient method of providing the needed
voltage is by using the Niles MVC HUB4 Speaker Distribution Hub. In the case of the
MVC100IR Infrared Sensing Volume Control, the necessary voltage is provided via the status
conductor of the CAT5 wire connecting the MVC100IR to the IR Main System Unit. Both
scenarios require that a 12VDC power supply be plugged into a 120volt switched outlet on the
audio receiver and run into the 3-30 volt status input on the MVC HUB4 or IR Main System
Unit. A sample-wiring diagram has been provided to help illustrate this.
Should you have any questions, please feel free to contact Niles Technical Support at 1-800-
289-4434 between the hours of 8am and 7pm Eastern Time, Monday through Friday.
Summary of Contents for MVC100IR
Page 1: ......
Page 2: ......
Page 3: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 13: ......
Page 14: ......
Page 15: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......