PROCEDURE FOR CHANGING THE HEPA FILTER

 

 
 
(1)  The precautionary steps described in this manual should be used when changing the 

HEPA filter. 

(2)  NOTE: You must follow Local and 1 or Federal guide lines when working with 

contaminated filters.  

(3)  Remove the eight (8) bolts holding the HEPA filter to the filter mounting plate, 

using a Phillips screw driver and a 11/32" wrench.  

(4)  Carefully remove the HEPA filter from the filter mounting plate, being careful not 

to create any airborne dust.  

(5)  This filter cannot be cleaned, and should be disposed of in an appropriate manner.  
(6)  Re-install the new HEPA filter using #8 screws, nuts, lock washers, and flat 

washers.  

(7)  Replace the impaction filter, on the HEPA filter. 
(8)  Re-connect the filter protector cage.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

Summary of Contents for 860240

Page 1: ...INSTRUCTION MANUAL MODEL 860240 55 GALLON DRUM ADAPTOR KIT...

Page 2: ...tc does exist Therefore when using this equipment in highly sensitive areas or where any release of particles above and beyond the minimum efficiencies would be detrimental and harmful to humans plant...

Page 3: ...prior to plugging the unit in 3 Prior to plugging in machine always inspect cord for cuts and exposed wires If these problems are found return the machine to an authorized service technician 4 Never...

Page 4: ...tank and snap the latches into place FILTER MAINTENANCE AND REPLACEMENT INSTRUCTIONS Warning When a loss of vacuum power is detected the vacuum should be turned off immediately Continued use of the ma...

Page 5: ...knot in the upper portion of the bag This is to insure that no dust particles escape while transferring to a proper container 7 Take a damp rag and wipe down the inside of the tank Dispose of contami...

Page 6: ...ng the HEPA filter to the filter mounting plate using a Phillips screw driver and a 11 32 wrench 4 Carefully remove the HEPA filter from the filter mounting plate being careful not to create any airbo...

Page 7: ...ME 1 2 520010 POWER CORD 1 3 520015 TOGGLE SWITCH 1 4 520004 DOME FELT 1 5 520016 FOAM RING 1 6 520304 MOTOR HOLD DOWN 1 7 520029 UPPER MOTOR GASKET 1 8 520365 MOTOR 1 9 520029 LOWER MOTOR GASKET 1 10...

Page 8: ...NO DESCRIPTION QTY REQ 1 520008 LID 15 GAL 1 2 520018 LID GASKET 1 3 520014 LID EDGING GASKET 1 4 520367 FILTER MOUNTING PLATE 1 5 520307 HEPA FILTER 1 6 520366 FILTER PROTECTOR CAGE 1 7 520316 IMPAC...

Page 9: ...ON ADAPTOR RING 520360 CONSISTS OF A 520306 55 GAL ADAPTOR RING B 860582 LID GASKET C 520220 INTAKE D 520217 INTAKE KNOB E 520216 INTAKE GASKET F 540001 DOWN TUBE ELBOW G 520019 LID LATCH 2 REQ 520318...

Page 10: ...tomer This warranty does not apply to normal wear and tear neglect misuse or incorrect installation If any other replacement parts filters or attachments are used other an original Nikro parts this wa...

Reviews: