External Device Connector
This connector can be used to communicate with an external device.
Before using the external device connector, make sure that the external device meets
the specifications below.
C
CAUTION –
Except for the connection shown in
, use of this connector
is at your own risk.
C
CAUTION –
Use only the male connectors specified above. Using other connectors will
damage the instrument.
The external device connector is a Hirose HR 10A-7R-6S female connector. The
pinouts for connecting it to an external device connector are shown below:
C
CAUTION –
Use only the pin connections shown above. Using other connections will damage
the instrument.
To communicate with an external device, connect the RS-232C signal from the
external device to Pin 1 (input terminal) and to Pin 2 (output terminal) on the
instrument.
Cap the data output/input connector securely while not in use. The instrument is not
watertight if the cap is not attached or not attached securely, and when the data
output/input connector is in use.
The instrument can be damaged by static electricity from the human body discharged
through the data output/input connector. Before handling the instrument, touch any
other conductive material once to remove static electricity.
System
RS-232C
Signal level
±9 V standard
Maximum baud rate
38400 bps asynchronous
Compatible male connector
Hirose HR10A-7P-6P or HR10-7P-6P
Pin
Signal
Description
1
RXD
Receive data (Input)
2
TXD
Send data (Output)
3
No connection
5
-
Ground
4, 6
No connection
HRS
1
6
2
5
3
4
Summary of Contents for NPL-322
Page 14: ...Contents xiv Total Station NPL 322 Instruction Manual ...
Page 38: ...2 Preparation 24 Total Station NPL 322 Instruction Manual ...
Page 68: ...3 Getting Started 54 Total Station NPL 322 Instruction Manual ...
Page 110: ...4 Applications 96 Total Station NPL 322 Instruction Manual ...
Page 154: ...5 Menu Key 140 Total Station NPL 322 Instruction Manual ...
Page 161: ...Total Station NPL 322 Instruction Manual 147 Checking and Adjustment 6 ...
Page 162: ...6 Checking and Adjustment 148 Total Station NPL 322 Instruction Manual ...
Page 172: ...8 System Diagrams 158 Total Station NPL 322 Instruction Manual ...
Page 188: ...9 Communications 174 Total Station NPL 322 Instruction Manual ...