background image

Nikon Callaway id TECH / Measurement and Display

External display and contents

After the power is turned on, the internal 
and external LEDs are illuminated until 
either the POWER or MODE button is 
pressed.

If 30 seconds pass without operation, the 
power turns off. Approx. one second 
before power turns off, this screen is 
displayed.

After measurement, all data “linear 
distance, horizontal distance, height and 
angle” are displayed. Units can be shown 
in meters, yards or feet. Angles are 
indicated by 

°(degree).

[  m ]  :  meter
[ YD ] :  yards 
[ f t ]   :  feet

Linear distance  

Horizontal distance

Height  

Angle  

Unit

[While measuring]

When the target is upward

When the target is downward

[Measurement unsuccessful or unable to measure]

When the target is upward

When the target is downward

With negative values, 

the “– (minus)” symbol is not shown.

[Measurement complete]

[Power On]

[Power off notice]

[Results]

1 Point Measurement

When the target is upward

When the target is downward

After measuring two points, 

"

Linear 

distance to two points

"

 and 

"

Vertical 

separation (height) and angle between 
two points

"

 are displayed. Units can be 

shown in meters, yards or feet. Angles 
are indicated by (degree).

Linear distance (1st point)

Linear distance (2nd point)

Vertical separation (height between two points.)

Angle of two points

Unit

Measure the distance between two points

[Measuring 1st point]

(Angle measurements never fail.)

[Results of 1st point]

[

Measuring 2nd point]

(Although the point  is located 
downward, display shows the 
upward position.)

(Angle measurements never fail.)

[Display of results for two points]

[Results]

[Failed to measure 1st point]

[Failure to measure 2nd point]

  8 

Power off 

Regardless of process, after 30 seconds 

30 seconds

   

 

since your last operation, power turns off. 

without operation

   

Operation/Results 

 

Work 

Button 

Display 

Display examples

  0  Switch for FULL/Limited 

 

Perform this operation 

MODE 

   

 modes 

 

 when power is off. 

+(follow by) POWER

   

Operation is complete 

(1) 

Initial screen

   

 

 

When switching to Limited mode

   

 

  When the symbol (shown on right) does not appear,  

 

   

 

 

 Limited mode is switched to Full mode.

   

 

  After approx. two seconds, proceed to (2).

   

 

(2) 

Measurement standby 

 

Last use symbol

  1 

Power On 

 

Initial screen 

POWER

 

All symbols (while pressing)

   

Measurement standby 

 

When this symbol (shown on right)

   

 

 

does not appear, Limited mode is set.

   

 

 

Measurement standby 

 

Last Use mode symbol

  2 

Selecting and setting   (1) 

Linear distance

3

 

 

 

n/a

    

Limited mode 

(2) 

Horizontal distance

4

】 

MODE 

 

n/a

    

  

(3) 

Height (from horizontal)

5

 

MODE 

 

n/a

    

  

(4) 

Angle (from horizontal)

6

 

MODE 

 

n/a

    

  

 

(5)  

Vertical separation (height between two points)

7

 

MODE

 

  blinks.  

n/a

    

  

   Return to 2-(1) Linear distance, then repeat. 

   

 

n/a

The angles and heights 

between two points are 

displayed only at the FULL 

mode setting.

Linear distance, Horizontal 

distance and height are 

displayed when FULL/Limited 

mode is set.

Initial screen (FULL mode)

   

Operation/Results 

 

Work 

Button 

Display

 

  Display examples

   

 

 

 

 

 

meter 

yards 

feet

   

 

 

 

  

 

Elevation(°)   Depression(°) 

 4     Measurement with horizontal distance mode
 4-1 

Seeking your target 

 

Horizontal distance 

 

   

(Align the reticle with target.)

 

4-2 

Measurement 

 

With the POWER button depressed, continuous measurement

 

POWER

 

 

   

(Laser irradiate symbol is displayed.)

 

 

is possible for up to 20 seconds. (When done, 4-3 display appear)

 

 

 4-3 

Failure to measure 

 

Repeat step 4-1. 

 

 

 4-4 

Measurement OK 

 

Horizontal distance 

  

 

201

 

220  660

  

   

 

 

Follow by 4-5 or 4-1.

 4-5 

Data display after

   

switching modes 

(1) 

Height (from horizontal)

5

 

MODE

 

 

45.0

 

49.2

 

146

   

 

(2) 

Angle (from horizontal)

6

 

MODE 

 

13

 

-13

   

 

(3) 

Vertical separation (height between two points)

7

 

MODE

 

blinks

 

   

 

(4) 

Linear distance

3

 

MODE 

 

206

 

225

 

676

   

 

(5) 

Horizontal distance 

MODE 

 

201

 

220

 

660

   

 

 

Return to 

4-5-(1), then repeat. 

MODE

   

 

 

(In Limited mode, return to 4-5-(1), then repeat (1), (4) and (5))

   

Operation/Results 

 

Work 

Button 

Display

 

 Display examples

   

 

 

 

 

 

meter 

yards 

feet

   

 

 

 

 

 

Elevation(°) 

  Depression(°) 

  3    Measurement with Linear distance mode
 3-1 

Seeking your target 

 

Linear distance

 

 

 

    (Align the reticle with target)
 3-2 

Measurement 

 

With the POWER button depressed, continuous measurement 

POWER

   

(Laser irradiate symbol is displayed.)

    

is possible for up to 20 seconds. (When done, 3-3 display appears.) 

 3-3 

Failure to measure 

 

Repeat step 3-1. 

 

 

 

 

3-4 

Measurement OK 

 

Linear distance 

 

 

206  225  676

   

 

 

Follow by 3-5 or 3-.1

3-5 

Data display after 

   

witching modes 

(1) 

Horizontal distance

【4】

 

MODE 

 

201  220  660

   

 

(2) 

Height (from horizontal

)【

5

 

MODE 

 

45.0  49.2  146

   

 

(3) 

Angle (from horizontal

)【

6

 

MODE 

 

13 

-13

   

 

(4) 

Vertical separation (height between 2 points)

7

 

MODE 

blinks

 

   

 

(5) 

Linear distance 

MODE 

 

206  225  676

   

 

 

Return to 3-5-(1) and repeat. 

MODE

   

 

 

(In Limited mode, return to 3-5-(1), then repeat (1),(2) and (5))

0 • 1 • 2

】 

Power On/Off and others

See the relevant section in this manual for each mode setting and display.

3

】 

Linear distance mode

  8 

Power off 

 

Regardless of process, after 30 seconds  

30 seconds

   

 

 

since your last operation, power turns off. 

without operation

Switching the measurement 

unit changes it for each 

mode. The POWER button 

can be used to measure in 

each mode.

The angle and vertical 

separation (height between 

two points) are displayed 

when set at FULL mode. 

Limited mode shows linear 

distance, horizontal distance 

and height.

  8 

Power off 

 

Regardless of process, after 30 seconds 

30 seconds 

   

 

 

since your last operation, power turns off. 

without operation

Measuring procedures and internal display

【4】

 Horizontal distance mode

Switching the measurement 

unit changes it for each 

mode. The POWER button 

can be used to measure in 

each mode.

The angle and vertical 

separation (height between 

two points) are displayed 

when set at FULL mode. 

Limited mode shows linear 

distance, horizontal distance 

and height.

   

Operation/Results 

 

Work 

Button 

Display

 

  Display examples

   

 

 

 

 

 

meter 

yards 

feet

   

 

 

 

 

 

Elevation(°)   Depression(°)

  6 

    

Measurement with angle mode setting (only at FULL mode setting)

 6-1 

Seeking your target 

 

Angle (from horizontal) 

 

   

(

Align the reticle with target.)

 6-2 

Measurement 

   

With the POWER button depressed, continuous measurement

 

POWER 

 

   

(Laser irradiate symbol is displayed.) 

 

is possible for up to 20 seconds. (When done 6-3 display appears)

 

6-3 

Failure to measure 

 

Repeat step 6-1. 

 

 

 6-4 

Measurement OK 

 

Angle (from horizontal) 

 

 

13 

-13

   

 

 

Follow by 6-5 or 6-1. 

 

 

5.2 

-5.2

 6-5 

Data display after

   

switching modes 

(1)  Vertical separation between two points

7

 

MODE

 

blinks

 

   

 

(2) 

Linear distance

3

 

MODE 

 

206  225  676

   

 

(3) 

Horizontal distance

4

 

MODE 

 

201  220  660

   

 

(4) 

Height

 (

from horizontal)

5

 

MODE 

 

45.0  49.2  146

   

 

(5) 

Angle (from horizontal) 

MODE 

 

13 

-13

   

 

 

Return to 6-5-(1), then repeat.

   

Operation/Results 

 

Work 

Button 

Display

 

 Display examples

   

 

 

 

 

 

meter 

yards 

feet

   

 

 

 

 

 

Elevation(°)  Depression(°) 

 5     Measurement with height mode

 5-1 

Seeking your target 

 

Height (from horizontal) 

 

   

(Align the reticle with target)

 5-2 

Measurement 

   

With the POWER button depressed, continuous measurement

 

POWER 

 

   

(Laser irradiate symbol is displayed.) 

 

is possible for up to 20 seconds. (When done, 5-3 display appear)

 5-3 

Failure to measure 

 

Repeat step 5-1. 

 

 

 5-4 

Measurement OK 

 

Linear distance 

 

 

45.0  49.2  146

   

 

 

Follow by 5-5 or 5-1.

5-5

 

Data display after

   

switching modes 

(1) 

Angle

from horizontal

)【

6

 

MODE 

 

13 

-13

   

 

(2) 

Vertical separation (height between two points)

7

 

MODE 

blinks

 

   

 

(3) 

Linear distance

3

 

MODE 

 

206  225  676

   

 

(4) 

Horizontal distance

4

 

MODE 

 

201  220  660

   

 

(5) 

Height (from horizontal) 

MODE 

 

45.0  49.2  146

   

 

 

Return to 5-5-(1) and repeat.

 

MODE

   

 

 

(In Limited mode, return to 5-5-(3),

   

 

 

then repeat (3), (4) and (5).

【5】

 Height mode

【6】

 Angle mode

Switching the measurement 

unit changes it for each 

mode. The POWER button 

can be used to measure in 

each mode.

See the relevant section.

The angle and vertical 

separation (height between 

two points) are displayed 

when set at FULL mode. 

Limited mode shows linear 

distance, horizontal distance 

and height.

  8 

Power off 

Regardless of process, after 30 seconds 

30 seconds

   

 

since your last operation, power turns off. 

without operation

【7】

 Vertical separation (height between two points) mode

   

Operation/Results 

 

Work 

Button 

Display

 

  Display examples

   

 

 

 

 

 

meter 

yards 

 feet

   

 

 

 

  

 

Elevation(°)   Depression(°)

  7 

    

Measurement with Vertical separation (height between two points) mode (only at FULL mode setting)

7-1 

Seeking your target 

 

Vertical separation (height between two points) 

 

blinks

   

(Align the reticle with target) 

 

(1st target)

7-2 

Measurement 

 

 

POWER 

 

   

(Laser irradiate symbol is displayed)

 

 

 7-3 

Failure to measure 

 

Follow by 7-1 

 

blinks

 

   

 

  Repeat 7-1, 7-2, 7-3 until measurement is complete.

 7-4 

Measurement OK 

 

Height of 1st target (from Horizontal) 

 

blinks

 

104  114  341

   

 

 

followed by 7-5 or 7-6.

7-5 

Data display after 

(1) 

Linear distance (1st target)

3

 

MODE 

 

247  270  810

   

switching modes 

(2) 

Horizontal distance (1st target)

4

 

MODE 

 

224  245  735

   

 

(3)  Height (from horizontal) (1st target)

5

 

MODE 

 

104  114  341

   

 

(4) 

Angle (from horizontal) (1st target)

6

 

MODE 

 

25

   

 

(5)  Vertical separation (height between two points) 

MODE 

blinks

 

0.0 

0.0 

0.0

   

 

 

7-5-(follow by 6-1 or 6-2)

   

 

(6-1) 

Return to 7-5-(1), then repeat. 

MODE

   

 

(6-2) 

follow by 7-3 or 7-4 

After aiming,

 

POWER

 

7-6 

Aiming (2nd target) 

 

Vertical separation (height between two points) 

 

blinks

 

104  114  341

   

(Align the reticle with target)

   

(2nd target)

   

 

  (Result shown is the height of the 1st target)

 7-7 

Measurement 

 

 

POWER 

 

    (Laser irradiate symbol is displayed)

   

 7-8 

Failure to measure 

 

Follow by 7-6 

 

blinks

 

   

 

 

Repeat 7-6,7-7 and 7-8 until measurement is complete

 7-9 

Measurement OK 

 

Vertical separation (height between two points) 

 

 

64.0  70.0  210

   

 

 

After 2 seconds move to7-10

 7-10 

 

 

Vertical separation (height between two points) 

 

blinks

 

64.0  70.0  210

   

 

 

Follow by 7-11 or 7-1

 7-11 

Date display after 

(1) 

Linear distance (2nd target)

3

 

MODE 

 

228  249  898

   

switching modes 

(2) 

Horizontal distance (2nd target)

4

 

MODE 

 

224  245  735

   

 

(3)  Height (from horizontal) (2nd target)

5

 

MODE 

 

40.0  43.8  131

   

  

(4)  Angle (from horizontal) (2nd target)

6

 

MODE 

 

10

   

  

(5)  Vertical separation (height between two points) 

MODE 

blinks

 

64.0  70.0  210

   

 

 

Follow by 7-11-(6-1) or 7-11-(6-2)

   

 

(6-1) 

Return to 7-11-(1), then repeat

 

MODE

   

 

(6-2) 

Follow by 7-3 or 7-4 

After aiming POWER

Switching the measurement 

unit changes it for each 

mode. The POWER button 

can be used to measure in 

each mode

See the relevant section.

If the mode is switched, the 

2nd target cannot be 

measured

Switching the measurement 

unit changes it for each 

mode. The POWER button 

can be used to measure in 

each mode

See the relevant section.

Switching the measurement 

unit changes it for each 

mode. The POWER button 

can be used to measure in 

each mode

See the relevant section.

  8 

Power off 

Regardless of process, after 30 seconds 

30 seconds

   

 

since your last operation, power turns off. 

without operation

  8 

Power off 

Regardless of process, after 30 seconds 

30 seconds

   

 

since your last operation, power turns off. 

without operation

Reviews: