JAA78071-R.3583.A
- L30 ・ AF-S 24-85/3.5-4.5G -
PREPARATION FOR INSPECTION AND ADJUSTMENT OF MAIN PCB
●
In case of replacing the main PCB, SWM unit or MR encoder unit, be sure to adjust the following items due to a
necessity on the operation.
1.
Items to adjust
・
Adjustment of MR duty
・
Adjustment of driving frequency and motor control
2.
Equipment and tools to be required
・
Single output rated voltage power supply: 1 unit
For contact A to mount: Output of the DC/DC converter (5.5V 100mA)
For contact F to contact G: 6.0V 3.0A
・
Oscilloscope: 1 unit for adjusting the MR duty/adjusting the driving frequency and motor control
・
AF-I communication box (J15306 or J15306-1): 1 unit
・
AF-I communication adapter (J15307): 1 unit
Summary of Contents for AF-S Zoom-Nikkor ED 24-85mm f/3.5-4.5G IF
Page 8: ...JAA78071 R 3583 A L6 AF S 24 85 3 5 4 5G SWM UNIT 96 3 B31 96 3 SWM unit ...
Page 13: ...JAA78071 R 3583 A L11 AF S 24 85 3 5 4 5G CAM RING 50 50 ...
Page 24: ...JAA78071 R 3583 A L22 AF S 24 85 3 5 4 5G 96 3 3rd LENS GROUP 3rd lens group ...
Page 46: ...JAA78071 R 3583 A F1 AF S 24 85 3 5 4 5G 外観図 Sketch drawings ...
Page 47: ...JAA78071 R 3583 A F2 AF S 24 85 3 5 4 5G 組立図 Structure of the Lens ...