EN
46
10-577
3. CONFIGURATION
3.1. Configuration options
The internal video unit can be programmed in 3 ways: manually, with the service unit 10-870 or with the Niko configuration software for access control
(programming interface 10-855 is required). Niko recommends programming with the configuration software.
Function
Manual
10-870
Niko configuration
software for access
control 10-854
Factory settings
Ringtone volume
x
–
x
Level 5 of 8
Speech volume
x
–
x
Level 7 of 8
Brightness
x
–
x
Level 7 of 8
Contrast
x
–
x
Level 7 of 8
Colour
x
–
x
Level 7 of 8
Video activation time
–
–
x
80 s
Select ringtones for door calls, internal calls and floor calls
x
–
x
door call 11
internal call 7
floor call 3
Ringtone for door call 2
x
–
x
same as door call 1
Serial number for 1. parallel assignment
–
x
x
1000000
deactivated
Serial number for 2. parallel assignment
–
–
x
1000000
deactivated
Function button assignment: control function 8, automatic door
opener, internal call or call forwarding
–
x
x
Control function 8
Call interruption following internal call on/off
–
–
x
OFF
Change audio external video unit limit
–
–
x
limit = 0
Call suppression
x
–
–
OFF
Block ringtone selection
–
–
x
OFF
Block ambient lighting on/off manually
–
–
x
OFF
Ambient lighting in standby on/off
x
–
x
ON
Ambient lighting as an additional incoming call notification
–
–
x
ON
Floor door opener on/off
–
–
x
OFF
Toggle between hands-free mode on/hands-free mode off
–
–
x
Hands-free mode
Switch between using the same speech volume for door and
internal calls/ adjusting the speech volume for door and internal
calls separately
x
–
x
together
Always transmit long door opener protocol
–
–
x
OFF
Door opens with a 3-second delay when automatic door opener
has been activated
–
–
x
OFF
Unlimited call time
–
–
x
OFF
Load factory settings
–
–
x
Summary of Contents for 10-577
Page 2: ...10 577 03 Nederlands 15 Fran ais 27 Deutsch 39 English 51 Sloven ina...
Page 63: ......
Page 64: ...10 577 PM010 57700R20451...