Removing again:
Push the key which was delivered with the product into the opening to disengage the device from the
mounting plate.
4. PROGRAMMING AND CHANGING SETTINGS
To assign the device to a bell push button
as the 1st or 2nd device
, see the user manual of the power
supply 10-80x or the user manual of the service device 10-870.
To add the device to an installation
as the 3rd or 4th device
on a bell push button, program it in parallel
(as SLAVE) with another internal unit (see section on programming with service device below).
Programming the function key with the service device 10-870
Connect the service device to the installation via the conductors a, b and P or via
the connector provided on the external unit. To program the internal video unit,
the programming must be activated one initial time. The serial numbers of the
internal and external units can be found on the devices and can be affixed to the
installation diagram for easier programming.
Example of a serial number
Activate programming
95 # serial no. internal unit #
Call diversion
90 # serial no. internal unit # serial no. internal unit for diversion #
“Ring-and-come-in” function
91 # serial no. internal unit #
Make an internal call
92 # serial no. internal unit # serial no. internal unit # to be
called
Transmit control function 8
93 # serial no. internal unit #
Light-switch function (standard)
94 # serial no. internal unit # 0 #
Connect the internal unit as
SLAVE to a MASTER
99 # serial no. internal unit # serial no. MASTER #
Switch off SLAVE programming
99 # serial no. internal unit # 0 #
Please note:
Only one of the functions above can be carried out.