26
10-511 (-50)
EN
Insert the cable via the opening at the back of the internal unit (fig.2). Install the base of the
internal unit at the desired height on a wall by means of the provided installation holes (fig.
2: 1). Connect two wires of the cable to terminals a and b of the internal unit. For systems
with over 80 internal units or systems with over 2 internal units that function in parallel, a
third wire is required (P-terminal). In this case, remove jumper J1 that is always fixed over
both contacts (fig.2: 2).
fig.2: bottom of the internal unit for wall fixing and connection of the internal unit
Click the front back on the base (fig.3):
1. Place the front on both fixings at the top.
2. Then click the bottom of the front on the base.
fig.3
1
2
1
2