SPECIFICATIONS
■
ASSEMBLY (cont.)
■
HOW TO USE
■
PART NAMES, DIMENSIONS
WARNING
CARE & STORAGE NOTES
LED STAND MAGNIFIER
4x Magnification lens SL-4
Type : White Glass lens
Magnification : ~4x
Viewable diameter : ~
φ
140mm
Head : Polycarbonate
Base : Steel
~1.8m
Lens cloth, 3.0mm hex wrench
Magnifying Lens
Material
Cord Length
Accessories
Rated voltage
Rated freq.
Rated power
Light source
Color temp.
Efficiency
Weight
Height
AC100V
50/60Hz
15W
84x white LED
~5,000K
(
daylight
)
100lm/W
~5.3
㎏
~430mm
2x Magnification
●
Item No.:SL-2
●
Magnification:~2x
●
Viewable area:~
φ
170mm
■
Makes work easy - Hands free; Well lit; Wide view.
LS4-150S
◆
Read and Follow for Safe Use of Product
■
BEFORE USE
Thank you for purchasing the LS4-150S LED Stand Magnifier.
Please read this manual thoroughly before use to insure proper operation and
long service.
●
To prevent electrical shock, always make sure power is OFF before assembly or
attaching/detaching lens or cleaning the equipment.
●
Never look at sun or bright light through the lens. There is risk of damage to eyesight.
●
Do not expose lens to sunlight or intense light, there is risk of starting fire.
●
Never leave lens in location where it can be exposed to direct or reflected sunlight.
Close the lens cover when not in use in order to prevent starting fire.
●
When installed on a sloped surface the unit may slip causing malfunction, damage, or
injury. Do not install on surface with incline of more than 5
°
from horizontal.
●
Do not use the power cord for lifting or moving, and never pull on the cord. There is risk
of the unit falling, or damage to the cord which may result in injury or fire.
CAUTION
●
Handle with Care. Do not drop, scratch, or use strong force with product. (Use special
care when cleaning.) Damage to product may cause injury.
●
Do not wash the lens with water. Water in long contact with lens may cause mold or
cloudiness.
●
The LED light is capable of frequent on/off cycles, but to avoid wear and damage to the
switch, do not cycle the switch unnecessarily.
●
This product contains metal bearing surfaces and may produce trace amount of dust
and powder due to repeated friction on metal surfaces. Therefore, it is not suitable for
clean-room applications. If there is concern over exposing workpiece to contamination,
do not use for that application or take care not to reposition light while above workpiece.
●
Base Plate surface may scratch table if slid upon it. To prevent damage, place protective
sheet or board under unit to protect the table.
●
Place workpiece on base plate, as moving the lens too far to the side may cause the
light to topple. Do not forcibly move any parts beyond their limits and use care to prevent
instability.
●
Please keep lens clean of dust and fingerprints.
●
Clean lens gently with dedicated lens cloth. Do not wash with abrasive cleaners, or rinse
with water.
●
Keep lens protection cover in down position, and unplug power cord when not in use for
extended period.
Instruction Manual
Niigata seiki Co., Ltd.
5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522 Fax. : +81-256-33-5518
MAIL [email protected]
URL http://www.niigataseiki.co.jp
■
Head Joint Range of Motion
③
Insert the Main Post all the way into the hole in the Support.
④
Secure with the Socket Head screw using the 3mm Hex Wrench.
⑤
Attach the Support Arm; make sure the Head Clamp is oriented
pointed down as shown in the diagram.
③
④
⑤
Base
Support Arm
Main Post
Arm Clamp
socket head
screw
3.0mm hex
wrench
Head Clamp
Hole for Main Post
Main Post Support
Orientation
○
○
×
×
~
80
°
max
~
30
°
max
Horizontal
Vertical
Head Clamp
×
×
×
×
Never rotate the head toward
the Support Arm beyond the
center of Lens.
●
For best results, and to prevent
eye fatigue, adjust the Arm so
that the Lens is parallel to the
surface you wish to inspect,
and securely tighten the Clamp.
※
The best lens position will
depend on distance between
eyes and the workpiece.
●
Plug in the cord and turn on the
Power Switch.
※
Position unit so that external
lights, such as the ceiling
fixtures, are not reflected in the
lens.
●
After use, close the Lens
Cover, turn off the Power
Switch, and unplug the Power
Cord.
■
Optional
Replacement Lens:
Power
Switch
approx. 280~410mm
Support Arm
Height : 430mm
Main Post Camp
Main Post
Power plug
Base
approx. : W240
×
D400mm
Lens Cover
Main Post
Support
Light Head
Clamp
Arm Clamp
Viewable area:
~
φ
140mm
Lens
※
Please Note: Due to product enhancements, appearance
and specifications are subject to change without notice.
ASSEMBLY INSTRUCTIONS
■
ASSEMBLY
●
CAUTION: Do not force the joint connecting the Light Head to the Support Arm
beyond its range of motion.
The joint will fail and create a hazardous condition
.
●
When first received, in order to avoid damage please use the following procedure
to remove the Light Head from the box and assemble.
①
Careful not to damage the cord, rotate the Support Arm horizontally
in the direction of the arrow.
②
Be careful of the cord while removing from the box.
◎
Move horizontally
※
It may cause damage
×
Do not lift arm up
Support Arm
②
①
※
Note, drawing omits ties,
cord, etc. for clarity. Actual
packaging may differ.
←
Video
demonstration!
https://youtu.be/
uUWNXm8rbmQ