background image

PP

        

PP

Object to be measured is positioned between these surfaces.
Measures external dimensions. Move Slide to open and close. 
Measures the height of steps.
Measures internal dimensions. Move Slide to open and close.
Position surfaces inside object to be measured.
Locks the Vernier Slide position.
Indicates measured value in 1mm graduations.
Bar for measuring depth. Bar moves in and out with Vernier Slide.
Depth is measured between these two surfaces.
Position thumb on knob for precise control of  vernier slide.
Scale for measuring with a resolution of 0.05mm.
Refer to following page for usage instructions.

Measuring Surfaces for outside measurements  

Outside Jaws 

…………………………………………

Measuring surfaces for step measurements

………

Inside Jaws

……………………………………………

Measuring surfaces for internal measurements  

Lock Screw

……………………………………………

Main Scale 

……………………………………………

Depth Bar  

……………………………………………

Measuring surfaces for depth measurements 

……

Thumb Knob 

…………………………………………

Vernier  Slide (Vernier Scale) 

………………………

Thank you for purchasing the Vernier Calipers (Kaidan Scale).
This product is a precision measurement tool with a main scale and a vernier scale to indicate the measured value.

For safe and proper use of this product, please read this instruction manual before use and follow the procedures described. 

Please keep manual where it is accessible to user for future reference.

Keep this manual with the instrument if transferred or leased to a third party.

For inquiries about this product, please contact dealer or Niigata Seiki at the address listed on the following page.

PART IDENTIFICATION AND FUNCTION

SAFETY PRECAUTIONS

Please Observe

Always follow the proper operating procedures in order to prevent 
harm to yourself or others, and to prevent damage to property. 

Read the manual and follow the instructions.

Use of product other than as described in the manual 

may cause accident.

Use only for measuring.

Use for any purpose other than measuring may 

damage or wear the instrument.  Improper use may 
also cause accident.

Handle with Care.

Do not drop or subject instrument to excessive shock. 

Do not place under heavy objects. Improper handling 
may cause damage or poor accuracy.

Do not scratch instrument, for example by writing ID 

number.

Indicates risk of personal injury or property damage if not followed.

WARNING

Use In Proper Environment

Please do not use instrument in rain or locations with 

excessive humidity. Do not use at extreme high or low 
temperatures. Keep out of direct sunlight.

Jaw Tips Are Sharp – Handle With Care.

Careless handling may cause injury.

Do not move the Vernier Slide when the Lock Screw 
is tightened.

Excessive force applied to Slide may cause damage or 

affect accuracy.

Do not disassemble or modify.

Do not remove the vernier slide, Please do not attempt 

to disassemble or modify as it may cause damage or 
poor accuracy.

Measuring surfaces for 

outside measurements

Outside Jaws

Measuring 

surfaces for step 

measurements

Measuring surfaces for internal measurements

Lock Screw

Thumb Knob

Vernier Slide (Vernier Scale)

Main Scale

Depth Bar

Measuring surfaces for 

depth measurements

Inside Jaws

VERNIER CALIPERS (Kaidan Scale)

PRECISION MEASURING TOOLS

GVC-

**

KDE

Model No.

User Manual

Denotes a prohibition - 

You MUST NOT do

Denotes a requirement - 

You MUST do

CALIBRATION

In order to maintain instrument accuracy, it is recommended that 
accuracy is confirmed through calibration on a periodic basis. 

Wear of measuring surfaces from repeated use may affect accuracy and periodic 
accuracy checks should be performed.

We provide calibration services.  
Please contact agent in country of 
purchase to make arrangements.

Model GVC-15KDE shown.

Reviews: