ProAxis

plus

™  Electric Profiling Bed and Pressure Area Care System  

Instruction for use and trouble shooting guide 

________________________________________________________________________________ 

ProAxis Plus Operating Instructions 3.1                Dated 18/05/11                                           15/24 

Smart Settings

Set the number of 

steps between the 

accepted angles

1 - 10

Once desired 

number is 

achieved press 

ACCEPT key

Set the number of 

minutes between 

steps

1 - 60

Once desired 

number is 

achieved press 

ACCEPT key

CONFIRM the 

settings, and if 

correct press 

ACCEPT key

If the settings are 

wrong, press the 

REJECT key and 

start again

Smart Settings

From the Home 

Screen press 

SMART key

Set backrest LOW 

position using UP / 

DOWN keys 

0 – 45 deg.

Once desired 

angle is achieved 

press ACCEPT 

key

Set backrest HIGH 
position using UP / 

DOWN keys
15 – 60 deg.

Once desired 

angle is achieved 

press ACCEPT 

key

If settings 

displayed are 

correct press 

ACCEPT

If settings are 

incorrect press 

REJECT and 

follow guide below 

Screen turns 

green and system 

is working. Time to 

next movement is 

displayed. 

Press EXIT key to 

stop at any time.

 

Summary of Contents for ProAxis Plus

Page 1: ...ea Care System Instruction for use and trouble shooting guide ________________________________________________________________________________ ProAxis Plus Operating Instructions 3 1 Dated 18 05 11 1...

Page 2: ...uk Website www nightingalebeds co uk Nightingale Care Beds Ltd declares that the ProAxisplus Electric Profiling Bed and Pressure Area Care System have been designed and manufactured to meet the follo...

Page 3: ...Profiling Bed Pressure Area System 1 1 Introducing ProAxisplus 1 2 Achievable Positions 1 3 The Mattress 2 Operations and Safety 2 1 Installing the ProAxisplus 2 2 Safety Precautions 2 3 ProAxisplus...

Page 4: ...ed pressure area care system that profiles to the contours of the human body by incorporating an automatic knee break whilst dropping the sacral area This unique profiling movement alleviates three ex...

Page 5: ..._____________________ ProAxis Plus Operating Instructions 3 1 Dated 18 05 11 5 24 1 2 Achievable Positions ProAxisplus can achieve many positions by easy operation of a simple handset Every function i...

Page 6: ...nd helps to dissipate moisture and perspiration away from the body It is common for modern mattresses to have anti bacterial covers but the Nightingale mattress now achieves the same standard internal...

Page 7: ...al should be pressed down into the lock position before any attempt is made to place a patient onto ProAxisplus Before placing the patient onto ProAxisplus the mattress platform should be profiled sli...

Page 8: ...ufficient clearance between the frame and the wall Care should be taken when the system is being moved and the power supply cable must be unplugged and stored with the system whilst in transit Battery...

Page 9: ...________ ProAxis Plus Operating Instructions 3 1 Dated 18 05 11 9 24 Operating Instructions in Diagrammatic Format 2 3 Main Features Backrest Removable Head Foot Boards Safety Buffers Dropping Hinge C...

Page 10: ...own Backrest To raise or lower the backrest of the platform the buttons marked Head Up and Head Down should be used Footrest To raise or lower the footrest the buttons marked Foot Up and Foot Down sho...

Page 11: ...e stopped anytime after two seconds into the movement by pressing ONE of the red CPR buttons once Tilt The system can be tilted by pressing one of the two green buttons on the lockout box marked Tilt...

Page 12: ...ws If the patient requires sitting up the backrest should be raised and the use of pillows for propping the patient up should be avoided Safety Sides Headboards The system will normally be supplied wi...

Page 13: ...ans that when the head section moves the thigh and foot sections move also Combining this movement with the proven capabilities of the Visco Elastic mattress gives the opportunity to offer a high degr...

Page 14: ...______________________________________________________ ProAxis Plus Operating Instructions 3 1 Dated 18 05 11 14 24 Smart Operation Screen Identification Home Screen Press BLUE function key below Smar...

Page 15: ...d number is achieved press ACCEPT key CONFIRM the settings and if correct press ACCEPT key If the settings are wrong press the REJECT key and start again Smart Settings From the Home Screen press SMAR...

Page 16: ...operating however the CPR function will still be available Once activated the CPR function will disable Smart until the programme is reactivated 5 Please ensure that the patient is able to tolerate mo...

Page 17: ...t exceed the safe working load of any equipment utilised to prevent manual handling issues The system works by calculating the enery required to lift the patient up and down as this is directly propor...

Page 18: ...ing Bed and Pressure Area Care System Instruction for use and trouble shooting guide ________________________________________________________________________________ ProAxis Plus Operating Instruction...

Page 19: ...viruses Nightingale treat blood or body fluid spills with NaDCC solution at 10 000 parts per million available chlorine Routing Decontamination NaDCC solution at 1000 parts per million available chlo...

Page 20: ...__________ ProAxis Plus Operating Instructions 3 1 Dated 18 05 11 20 24 All of the above Important If there is any doubt as to what solution of cleaning agent is required for the various cleaning proc...

Page 21: ...em is supplied with a 3 year warranty subject to servicing annually covering labour and parts that may require replacing through normal use It is recommended that every system is serviced annually to...

Page 22: ...Foot Rest Angle 0 17 Degrees below electric variable Knee Break Electric Auto Variable CPR Electric Auto Mass 165kg Capacity 318kg Safe Working Load 353kg Trendelenburg Tilt 12 5 Degrees Reverse Tren...

Page 23: ...ed by a red screen If in Smart Weigh Mode press exit then press manual If the confirm settings screen is displayed press manual Transformer Batteries Is the transformer attached plugged into the wall...

Page 24: ...______________________________ ProAxis Plus Operating Instructions 3 1 Dated 18 05 11 24 24 Total after sales service Our aftersales and Helpline are always available Nightingale Care Beds Ltd Unit 1...

Reviews: