Product description: Gas Forced Heater/ LPG 50KW

   

Model: CT2141 

 

Applicable EC Directives: 

EC Low Voltage Directive 2014/35/EU 

EC Directive of Electromagnetic Compatibility 2014/30/EU 

     

Harmonized standards 

EN 55014-1:2006/+A1:2009/+A2     EN 55014-2:1997/+A1:2001/+A2 

EN 61000-3-2        EN 61000-3-3 

EN 60335-2-30:2009+A11     EN 60335-1:2012+AC:2014+A11    EN 62233

 

 

20 Station Road, Rowley Regis, West Midlands, B65 0JU.U.K. 

Mr. Gurcharan Tony Singh Sanghera 

Managing Director

 

CANNON TOOLS LTD 

                                             

 

2018-08-07 

 

Model CT2141 

Rating 170.600BTU 

(50kw) 

Fuel Consumption 

3.63kg/h 

Fuel Orifice Port Size   

1.4mm 

Air Flow Temp. 

360

 

Type Of Gas 

For use with LPG only 

Gas Supply Pressure 

1500mBar     

Electricity Input 

220-240V~ 50Hz 

Ignition piezo 

Primary Flame Control 

Thermal Probe Operated Gas Valve 

Overheating Protection 

110

       

 

 
 

Summary of Contents for CT2141

Page 1: ...RIGINAL INSTRUCTIONS Cannon Tools Limited Address 20 Station Road Rowley Regis West Midlands B65 0JU UNITED KINGDOM SAVE THESE INSTRUCTIONS AND PRECAUTIONS READ ALL PRECAUTONS AND INSTRUCTIONS BEFORE...

Page 2: ...w Voltage Directive 2014 35 EU EC Directive of Electromagnetic Compatibility 2014 30 EU Harmonized standards EN 55014 1 2006 A1 2009 A2 EN 55014 2 1997 A1 2001 A2 EN 61000 3 2 EN 61000 3 3 EN 60335 2...

Page 3: ...bove and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe w...

Page 4: ...ards the cylinder 1 5 Use only the supplied pressure regulator 1 6 Never use the heater without its cover 1 7 Do not exceed 100W m of free room The minimum volume of the room must be larger than 100m...

Page 5: ...pletely Do not produce sparks or free flames 1 19 If in any doubt contact your supplier 2 INSTALLATION 2 1 Connect the heater to a suitable electric socket 230V 50Hz 2 2 Make sure that the machine is...

Page 6: ...If ignition is difficult or irregular before repeating the ignition operations make sure that the fan is not locked and the air inlet and outlet are unobstructed 3 2 SWITCH OFF To stop the heater shut...

Page 7: ...ect a propane leak keep out of all low areas 5 Use your neighbor s phone and call your fuel gas supplier and your fire department Do not reenter the building or area 6 Stay out of the building and awa...

Page 8: ...and clean it The solenoid gas valve is not open Check that the solenoid valve works There is no spark Check the position of electrode The burner lights up but after few seconds the heater stops No co...

Page 9: ...e control no At minimum heat output elmin N A kW Two or more manual stages no room temperature control yes In standby mode elSB N A kW with mechanic thermostat room temperature control no with electro...

Page 10: ...cy in active mode S on 100 Correction factor F1 0 Correction factor F2 0 Correction factor F3 0 Correction factor F4 0 Correction factor F5 0 Biomass label factor BLF 1 The seasonal space heating ener...

Reviews: