OXYGEN CONCENTRATOR

Federal Law (US) restricts this device to
sale or use by, or on the order of, a licensed
physician. This oxygen concentrator should
be used only under the supervision of a
licensed physician.

IV.

USEFUL INFORMATION................................... 4

IV.1. Accessories and spare parts.......................................4
IV.2. Materials in direct or indirect contact with patient....4
IV.3. Operating principles..................................................4
IV.4. Alarms - Safety devices............................................5
IV.5.

Indicator light function

...........................................

5

IV.6. Technical characteristics...........................................5
IV.7.

Standards..................................................................6

IV.8.

Method for disposing of waste.................................6

IV.9.

Method for disposing of device................................6

IV.10. Troubleshooting........................................................7

APPENDIX A EMC INFORMATION......................8,9

CONTENTS

: ON (power switched on)

: Off (power switched off).

: Type B device

: Class II protection

:  Do not expose to open  ames.

: Do not use oil or grease.

: Technical information.

: Consult the accompanying documents.

: Keep in the vertical position.

: Fragile - handle with care.

GLOSSARY OF SYMBOLS

[Original language is English ]

GLOSSARY OF SYMBOLS..........................................1

GENERAL SAFETY GUIDELINES ............................2

I.

DESCRIPTION .....................................................

2

I.1.

Front panel (Fig. I. 1)............................................ 3

I.2.

Rear panel (Fig. I. 2)................................................3

II.

STARTING-UP / INSTALLATION .....................3

II.1. Use in direct oxygen therapy...................................3

III. CLEANING-MAINTENANCE ............................4

III.1. Cleaning ...................................................................4
III.2. Everyday disinfection ...................................................4
III.3. Maintenance.............................................................4

Danger: Do not smoke when using oxygen

or when near this device.

StockCheck.com

Summary of Contents for Mark 5 Nuvo Lite Family

Page 1: ...6 IV 9 Method for disposing of device 6 IV 10 Troubleshooting 7 APPENDIX A EMC INFORMATION 8 9 CONTENTS ON power switched on Off power switched off Type B device Class II protection Do not expose to o...

Page 2: ...tor are not considered to be responsible themselves for the consequences on the safety reliability and characteristics of a device unless Theassembly tting extensions adjustments modi cations or repai...

Page 3: ...ower cable into a power outlet of the correct voltage and frequency as de ned on the manufacturer s technical label Fig I2 10 f Press the power switch I O to the ON position I The red indicator will l...

Page 4: ...ftheMARK5NuvoLITE istobecleaned with a soft dry cloth or if necessary a damp sponge then thoroughly dried with wipes and an alcohol based solution Acetone solvents or any other in ammable products mus...

Page 5: ...dels Class II device with insulated casings EN60601 1 stan dard Pressure A safety relief valve calibrated to 2 7 bar 40 psig is tted on the compressor outlet IV 5 3 Maintenance of the system alarms No...

Page 6: ...dofusingthemethodsappropriate to the civil authority of the location where disposed IV 9 Method for disposing of the device In order to preserve the environment the concentrator must only be disposed...

Page 7: ...eumatic circuit fault Compressor thermal safety device has been activated Fan is not working Dirty Filters Tubedisconnected orhumidi er not tight Cannula tubing is kinked Observations The I O ON OFF b...

Page 8: ...8 Jan 2011 2010 8400 Rev F S t o c k C h e c k c o m...

Page 9: ...9 Jan 2011 2010 8400 Rev F S t o c k C h e c k c o m...