21
Call up internal 45 circle, then grind lens in metal Hi-curve mode. Check the size and
adjust it.
Bevel height (HCrv)
Adjustment Parameter:
Press and hold
(
STOP
)
,
then press
to go to Parameter screen. Select
Parameter setting, then press
. Scroll the page to
Parameter setting
(Page
11/12)
Bevel height (HCrv)
:
0.00mm
1. Call up internal 45 round. Press START. After LMU measures, in Bevel Simulation
Screen,
change “TILT” value to 0.0
, then press START.
2.
Check the height of bevel. If not 0.8mm please adjust it 0.8mm. If higher than 0.8mm
please decrease the value. If smaller than 0.8mm please increase the value.
+
0.8mm
–