The ST-320BL is a portable or permanent mount 

stroboscope.

 

Utilizing super bright high-powered black light 

LED lamps, these stroboscopes are perfect for UV ink printing 
applications. The ST-320BL’s LED array provides a bright, stable 
strobe light over a wide measurement range with a lifetime far 
exceeding xenon lit stroboscopes. Operation is simple with the 
8 button keypad and quick rate adjustment dial, combined with 
large, backlit LCD display. Phase shift, flash duration, plus flash 
rate are all quickly adjustable. The unit can work off user adjusted 
flash frequency or from a remote sensor’s signal which will auto-
matically adjust to corresponding process fluctuations. 

The ST-320BL is designed for speed and frequency measure-
ments in the printing, packaging, textile, automotive, cable, min-
ing, steel, chemical, optical and medical industries in various ap-
plications.

ST-320BL LED Stroboscope Array

Operation Manual

SHIMPO INSTRUMENTS

Use in flammable environments is prohibited. Use in this manner may 

result in fire or explosive.

Don’t look directly into the LED light Source. This may result in eye in-

jury.

Don’t use or store in the following environments. Direct sunshine con-

densation, dust or caustic.

Do not alter, or modify of improperly. Such action may cause damage 

and void warranty.

Operate with 0-35°C (32-95°F), 35-85% RH. Use outside of this range 

may alter operation of the unit.

Case may become excessively hot when used continuously for more 

than 2 hours. Mount unit on a tripod or other fixed device.

SPECIFICATIONS

Flash Rate Range: 60 to 120,000 FPM ; 1-2000 Hz

Accuracy: 0.01%±1 digit of F.S. @ 77° F (25°C)

Lamp: 9 black light LED’s; 415 to 420 nm wave length.

Lamp Lifetime: Approximately 3~5 years depending on usage.

Display: Backlit LCD

Resolution: 60 ~12,000 FPM = 0.1 FPM; 12,001~120,000 FPM 

= 1 FPM; 1~200 HZ = 0.01 Hz; 201~2000 = 0.1 Hz

Flash Duration: 0.1°- 2.5°

Phase Shift: 0-359°

Power Requirement: ST-320BL-1: 100-120 VAC; ST-320BL-2: 

Rechargeable Battery. 

Battery: (ST-320BL-2) Lithium DC 10.8V 2000mA

Battery Life: (ST-320BL-2): Approx. 12 hrs depending on settings

Input Signal: 12 V Pulse Input; Mini-USB.

Input Signal Range: 60-120,000 FPM (1-2000 Hz) 

Input Pulse Width: Over 50 µs 

Input Signal Flash Delay: 0-999 ms; 0-359°

Temperature Limits: 32-95°F (0-35°C) 

Humidity Limits: 35 to 85% RH 

Enclosure: Aluminum & ABS

Mounting: 1/4-20 UNC Thread

Enclosure Rating: IP54 

Product Weight: ST-320BL-1: 1.85 lb (0.84 kg); 

ST-320BL-2: 1.98 lb (0.90 kg)

Package Weight: ST-320BL-1: 4.40 lb (2.0 kg); 

ST-320BL-2: 5.73 lb (2.6 kg)

Approvals: CE

Warranty: 1 year

Included Accessories: Carrying Case, ST-320BL-1:  6.5’ (2 m) 

AC power cord; ST-320BL-2: Power Recharging Adapter with cord.

Operation Panel Located on Control Enclosure

POWER: Power on and off. 

MODE: Select mode of operation or Parameter Menu: Internal/

External/Parameter Settings

SET: Change Units (FPM to Hz); In Parameter Menu scroll through 

parameter settings, Store setting values.

x2: Multiplies the flash rate/frequency by a factor of 2.

1/2: Divides the flash rate/frequency by a factor of 2.

RATIO: Adjusts flash duration (flash pulse width) in Internal/Ex-

ternal modes.

“+”: Advance image forward 3 degrees at a time in internal mode. 

In parameter setting mode, adjusts setting values.

“-”: Retard image backwards 3 degrees at a time in internal mode. 

In parameter setting mode, adjusts setting values.

Dial: Set flash rate or frequency. CW: Increase flash rate/frequen-

cy. CCW: Decrease flash rate/frequency. (Turn dial quickly to 

drastically change value; Turn dial slowly to change value by 1 

digit.) In parameter setting mode, CW or CCW rotation chang-

es the setting value. *Dial located on side of unit.

Summary of Contents for Shimpo ST-320BL

Page 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Page 2: ...ly 3 5 years depending on usage Display Backlit LCD Resolution 60 12 000 FPM 0 1 FPM 12 001 120 000 FPM 1 FPM 1 200 HZ 0 01 Hz 201 2000 0 1 Hz Flash Duration 0 1 2 5 Phase Shift 0 359 Power Requiremen...

Page 3: ...Parameter setting menu section Internal Flashing Mode Changing Units of Measure in Internal Mode To change the measuring units from FPM to Hz press and release the SET key Units will alternate with e...

Page 4: ...he x2 key Phase Shift Angle First press SET key then enter this mode When the rotation speed of the target object and the flash rate of the ST 320BL becomes equal the phase shift function can be used...

Page 5: ...nters EXTER 1 In this mode frequency HZ or speed FPM automatically flash according to the external trigger signal After setting the parameters generally the detected object has an advanced or lag phen...

Page 6: ...ll go to 0 as the angle increases past 359 Delay angle decreases as the dial is rotated to the left The set tings will eventually go to 0 as the angle decreases past 359 Parameter Settings To enter pa...

Page 7: ...n using battery power Flashing will resume with either a dial rotation movement or a keypad operation The LED auto shutoff will not occur in External trigger mode while a signal is being received by t...