Nidec Shimpo 329BL Operation Manual Download Page 7

Back Light Setting
The LCD display of the ST-329 stroboscope has a backlight that 
can be turned on or off in the parameter settings. To adjust the 
backlight setting, enter parameter mode and use the “SET” key to 
cycle to LCD setting. Press “+” key to turn on the backlight. Press 
“-” key to turn off the backlight.

Note: If the backlight is set to on, as a power saving feature, it will 
automatically shut off after the set minutes if no keypad or dial 
operation has occurred. The LCD backlight will turn back on with 
keypad or dial operation.

Automatic Power-Saving Settings 

LCD Back Light Off: If the backlight is set to on, as a power 
saving feature, it can be adjusted to automatically shut off from 
1 to 1000 seconds, if no keypad or dial operation has occurred. 
The LCD backlight will turn back on with keypad or dial oper-
ation.

Factory Reset (Initial)
To reset unit to factory values choose “Yes” under Initial in the 
parameter setting mode. Then press “SET”.

7

Model

Length

# LED 

Groups

# LED’s

ST-329-0

9.25” (235 mm)

2

18

ST-329-1

20” (500 mm)

3

27

ST-329-2

24” (600 mm)

4

36

ST-329-3

31” (800 mm)

6

54

ST-329-4

39” (1000 mm)

7

63

ST-329-5

39” (1000 mm)

8

72

ST-329-6

47” (1200 mm)

9

81

ST-329-7

47” (1200 mm)

10

90

ST-329-8

63” (1600 mm)

11

99

ST-329-9

65” (1650 mm)

12

108

Dimension Chart & Light Arrangement

Summary of Contents for Shimpo 329BL

Page 1: ...ustin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and mea...

Page 2: ...hours Mount unit on a tripod or other fixed device SPECIFICATIONS Flash Rate Range 60 to 120 000 FPM Accuracy 0 01 1 digit of F S 77 F 25 C Lamp Lifetime Approximately 3 5 years depending on usage Di...

Page 3: ...djustments turn the dial slowly For quick adjustments rotate the dial quickly The flash rate range and resolution will be different according to the selected measur ing range One function of a strobos...

Page 4: ...the x2 key Phase Shift Angle First press SET key then enter this mode When the rotation speed of the target object and the flash rate of the ST 329 becomes equal the phase shift function can be used t...

Page 5: ...er setting the parameters generally the detected object has an advanced or lag phenomenon To adjust press the or for fine tuning change the perimeter parameters so that detected object achieves a stil...

Page 6: ...go to 0 as the angle increases past 359 Delay angle decreases as the dial is rotated to the left The set tings will eventually go to 0 as the angle decreases past 359 Parameter Settings To enter param...

Page 7: ...utomatic Power Saving Settings LCD Back Light Off If the backlight is set to on as a power saving feature it can be adjusted to automatically shut off from 1 to 1000 seconds if no keypad or dial opera...

Reviews: