background image

1. LCD SCREEN STANDARD VIEW

Test Mode Icons: 

2. Battery icon: Battery level or charging status. Flashes when   

    gauge needs to be recharged.

3. OK/OV Indicator: 

4. Force Icons: Indicates force direction.

5. Current measured value

6. Analog bar: Indicates current position within full scale. When  

   the bar enters the area enclosed by the dotted line, this 

   signifies the full scale capacity is exceeded by an overload 

   condition.

7. Storage icon: Indicates data is being saved.

8. System time

9. Units Indicator: Selected engineering unit.

10. Load Cell Capacity Icon: 

2

1

2

3

4

9

8

7

6

5

10

Under Lower Limit

Between Low Limit & Upper Limit

Over Upper Limit

Tension

Compression

Track: Real Time, live measuring mode

Peak: Reading will not change until a higher value is mea-
sured
AutoPeak: When Peak Time is up, resets peak value automat-
ically
First Peak: Captures First Peak after drop ratio decrease has 
been detected. Drop Ratio set in menus.

If no load cell is connected, this symbol appears & blinks

2. LOAD CELL CAPACITY & RESOLUTION TABLES

Digital View

Graphic View

1

3

5

9

8

2

7

10

6

S-Beam for 

Compression or 

Tension

N

kgf

lbf

kN

klbf

tf

S-1

M-1

Capacity

1000

100

220

-

-

-

Resolution

0.1

0.01

0.05

-

-

-

S-2

Capacity

2000

200

450

-

-

-

Resolution

0.5

0.05

0.1

-

-

-

S-5 

M-5

Capacity

5000

500

1100

-

-

-

Resolution

1

0.1

0.1

-

-

-

S-10 
R-10

M-10

Capacity

10000

1000

2250

10

-

-

Resolution

1

0.1

0.5

0.01

-

-

S-20

Capacity

-

2000

4500

20

-

-

Resolution

-

0.5

1

0.005

-

-

R-50

M-50

Capacity

-

5000

-

50

11

5

Resolution

-

0.5

-

0.005

0.001

0.0005

R-100

M-100

Capacity

-

-

-

100

22

10

Resolution

-

-

-

0.01

0.005

0.001

R-200

Capacity

-

-

-

200

44

20

Resolutiion

-

-

-

0.05

0.01

0.005

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for FG-7000L

Page 1: ...Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test Whether the unit is ON or OFF DO NOT exceed the capacity of the sensor NEVE...

Page 2: ...gher value is mea sured AutoPeak When Peak Time is up resets peak value automat ically First Peak Captures First Peak after drop ratio decrease has been detected Drop Ratio set in menus If no load cel...

Page 3: ...to cancel or touch MENU to confirm and exit Figure 4 2c Figure 4 2c 4 2 2 Group When several test samples need to be measured the sam ples can be coded into groups The range is 01 99 When set to 00 b...

Page 4: ...ENU to confirm and exit Figure 4 3b Single At the home screen pressing the LOG stores the cur rent displayed value If the default settings key is for storage See 4 5 8 key setting Series Continuous da...

Page 5: ...rs may be set per Fig ure 4 5a 4 5b Figure 4 5a Figure 4 5b 4 5 1 Display Mode Two display modes may be selected Digital and Graphic Fig ure 4 5c Figure 4 5c 4 5 2 Display Direction Select the mode of...

Page 6: ...can restore it to the factory default settings Carefully use this function Figure 4 5l Figure 4 5l 4 6 Language Select between English German and Chinese Figure 4 6a Figure 4 6a 4 7 Calibration Users...

Page 7: ...1a The USB Port can be connected to a charger with the USB cable for charging the internal Ni MH battery and can be connected to a computer for uploading the measured values Connect the gauge and the...

Page 8: ...sions W H B M 1kN 51 76 2 25 4 M12X1 75 2kN 5kN 10kN 20kN Capacity Dimensions mm D d L H SR DI M 10kN 32 8 14 16 16 24 5 3 M5 20kN 38 11 30 50kN 82 22 32 44 50 68 4 M8 100kN 200kN 100 28 36 48 120 80...

Reviews: