Figure 4-7 Multiple drives with single grounding bracket
If installing multiple drives, one grounding bracket can be used for two drives.
Figure 4-5 Grounding bracket at the top of drive Figure 4-6 Grounding bracket at the bottom
of drive
Grounding bracket and drive to be directly
connected to a grounded backplate.
1
1. The distance for EMC (shown in Figure 4-6 above) from the drive is as follows:
200 V drive - Allowance up to 65 mm (2.56 in)
400 V drive - Allowance up to 100 mm (3.94 in)
NOTE
The grounding bracket can remain mounted when the drive is removed as follows.
NOTE