![background image](http://html1.mh-extra.com/html/nidec/5200250/5200250_power-installation-manual_1687772083.webp)
Unidrive M/HS Frame 5 to 6 Power Installation Guide
83
Issue Number: 9
S
P
M
E
Te
UL
li
Table 5-3 575 V drive ratings (500 V to 575 V ±10 %)
Model
Normal Duty
Heavy Duty
Max
cont
output
current
Nominal
power at
575 V
Motor
power at
575 V
Peak
current
Max
cont
output
current
Open
loop
peak
current
RFC
peak
current
Nominal
power at
575 V
Motor
power at
575 V
A
kW
hp
A
A
A
A
kW
hp
05500030
3.9
2.2
3
4.3
3
4.5
6
1.5
2
05500040
6.1
4
5
6.7
4
6
8
2.2
3
05500069
10
5.5
7.5
11
6.9
10.3
13.8
4
5.0
06500100
12
7.5
10
13.2
10
15
20
5.5
7.5
06500150
17
11
15
18.7
15
22.5
30
7.5
10
06500190
22
15
20
24.2
19
28.5
38
11
15
06500230
27
18.5
25
29.7
23
34.5
46
15
20
06500290
34
22
30
37.4
29
43.5
58
18.5
25
06500350
43
30
40
47.3
35
52.5
70
22
30