9.6  Electrical connections

PFP 1.35kW 1-Phase

PFP 2.6kW 3-Phase

PFP 4kW 3-Phase

REF.

DESCRIPTION

1

Power supply

2

Control board connection

3

Communication

4

Blinking LED

5

Relay connection

PE              Y/GREEN

W               BLACK

V                BROWN

U                GREY

NO
C

T
S

PE

R

                     TACHO/ALARM/FILTER

GND
MODBUS - B
MODBUS - A
GND

                   TRANSDUCER INPUT

    ANALOG INPUT

ENABLE
+10V
+24V

U                 GREY

V                 BROWN

W                BLACK

PE               Y/GREEN

CN

O

R
PE

ST

    ANALOG INPUT

ENABLE

+10V

+24V

                   TRANSDUCER INPUT

GND
MODBUS - A
MODBUS - B
GND

TACHO/ALARM/FILTER

PE

L

N

ANALOG INPUT

ENABLE

+10V

+24V

TRANSDUCER INPUT
GND
MODBUS - A
MODBUS - B
GND

TACHO/ALARM/FILTER

U                 GREY

W                BLACK

PE               Y/GREEN

V                 BROWN

1

2

3

1

2

1

2

5

5

4

3

4

3

4

Summary of Contents for PFP

Page 1: ...Rev 0 05 11 2020 EC FAN PFP OPERATING MANUAL Regal Beloit Italy S p A Via Modena 18 24040 Ciserano BG ITALY Phone 39 035 873 111 Fax 39 035 884 319 www regalbeloit com...

Page 2: ...CRIPTION 12 8 TECHNICAL FEATURES 13 8 1 Dimensional drawings 13 9 INSTALLATION 14 9 1 Commisioning 14 9 2 Operation 14 9 3 Ambient operating condition 14 9 4 Fan installation 14 9 5 Accessory installa...

Page 3: ...he system 31 11 2 How to calculate volume flow rate from pressure probe 32 12 OTHER FEATURES 33 12 1 Filter alarm 33 12 2 Out of functioning range alarm 33 12 3 Flying start for 3 phase only 33 12 4 R...

Page 4: ...egister 38 18 3 Holding register description 39 18 4 Input register description 44 18 5 Fan info and Modbus registers 45 19 ALARM HANDLING 46 19 1 Monitoring 46 19 2 Modbus registers Alarm description...

Page 5: ...e user of the potential personal damage that may result from an incorrect use of the machine or from the non compliance with the use and maintenance instructions Failure to comply with these safety me...

Page 6: ...e the PFP fan is installed Before doing any maintenance make sure that the power supply and the batteries have been disconnected Install an all pole disconnecting device in the power supply system in...

Page 7: ...nical Service has repaired it Theinstaller and themaintenance man must know the content of this manual Although themain features of theequipment described in this manual are not subject to change the...

Page 8: ...vide harmonics filtering and compliance with the EMC requirements applicable to domestic and equivalent environments first environment or with the advanced re quirements for harmonic distortion which...

Page 9: ...NO 5 NO PHASES CURRENT TYPE 6 ELECTRICAL FREQUENCY 7 VOLTAGE 8 IP PROTECTION GRADE 9 MOTOR INSULATION CLASS 10 CAPACITOR VALUE WHEN PRESENT 11 MAXIMUM CURRENT INPUT 12 MOTOR RATED POWER 13 RATED RPM...

Page 10: ...shall not exceed two years since fan production or since operating the fan for at least half an hour continuously The storage site shall have a temperature between 20 C and 70 C a Relative Humidity lo...

Page 11: ...he PFP fan check to ensure that all of the items listed are present and that there are no visible signs of damage 1 Remove the fan from the box 2 Remove all the components from the packaging WARNING W...

Page 12: ...hich allow consuming significantly less power than conventional AC motors This occurs at all speed levels especially with partial load operation The EC complete drive system i e the combination of the...

Page 13: ...20 C 40 C IP 54 355 1416F6 1431F3 3 Ph 3 24 2110 20 C 40 C IP 54 400 1416F1 1431F2 1 Ph 5 74 1347 20 C 40 C IP 54 400 1416F5 1431F3 3 Ph 4 2600 20 C 40 C IP 54 450 1416F1 1431F2 1 Ph 5 71 1327 20 C 4...

Page 14: ...be removed from the related PFP fan type and size The driver cannot be used separate from the related fan WARNING WARNING Ensure correct grounding connections The ground cable must be enough to carry...

Page 15: ...t protection guard kit Materials 235 JR steel according to UNI EN 10025 Surface Fe Zn 8 according to UNI EN ISO 2081 Assembly In order not to lose the alignment proceed as follows overlap the protecti...

Page 16: ...nnection PE Y GREEN W BLACK V BROWN U GREY NO C T S PE R TACHO ALARM FILTER GND MODBUS B MODBUS A GND TRANSDUCER INPUT ANALOG INPUT ENABLE 10V 24V U GREY V BROWN W BLACK PE Y GREEN CN O R PE ST ANALOG...

Page 17: ...Work on the driver fan by unqualified personnel or failure to comply with warnings can result in severe personal injury or serious damage to material Only suitably qualified personnel trained in the...

Page 18: ...A GND Analog Input Enable 10V No C PE R S T 24V Transducer input 6 8 4 1 7 2 5 4 3 2 1 Grey Brown Blue White Yellow Red Pink Yellow Green Black 3 Black 2 Black 1 Connector code 144144 Connector code...

Page 19: ...FP 1 35kW 1 Phase Single Phase 220 240V 10 50 60Hz The performance in the range 200V 264V 50Hz 60Hz is always the same due to the PFC module inside the driver Min and max wire section Spring loaded pu...

Page 20: ...4V 5 TRANSDUCER INPUT 6 GND 7 MODBUS A 8 MODBUS B 9 GND 10TACHO ALARM FILTER 4ANALOGINPUT 3 ENABLE 2 10V 1 24V 5 TRANSDUCER INPUT 6 GND 7 MODBUS A 8 MODBUS B 9 GND 10TACHO ALARM FILTER 10 1 10 1 10 1...

Page 21: ...driver default mode and the signal must be connected into the ANALOG INPUT and the reference to GND The analog input can accept also a PWM signal with f 1kHz See also paragraphs 9 6 4 3 and 14 3 WARNI...

Page 22: ...occurs when a fan is forced to run forward or backward rotation with a speed higher than 150 rpm If an ext 4 20mA device is used it is necessary to add 0 1 precision resistances between the ANALOG INP...

Page 23: ...ion 2 With the driver powered off through an UART serial connection To connect OFFLINE the driver to a PC when the fan is powered off a USB to UART converter can be used K431A6 for 1 phase drivers and...

Page 24: ...he kind of transducer used 1 Open Control Loop Transducer 2 Closed Control Loop Transducer Nicotra Gebhardt can provide a Pressure Transducer code K43198 If the transducer does not have its own contro...

Page 25: ...control thesignal mustbeconnected tothestandard ANALOGINPUT 9 6 4 6 Relay for PFP 3 Ph only A relay is available on the Three Phase drivers It is suitable for 250Vac 30Vdc 5A When the driver is powere...

Page 26: ...GND The max current supplied of the output is 0 2mA Remember that the SpeedReal is 0 whenever the required speed is lower than Speedmin unless the fan is in the dragging phase The same analogue output...

Page 27: ...MAX and min speed default values are in function of the fan sizes 10 1 1 Analog speed control INPUT TYPE 0 Through this setting the fan runs at the speed defined by modifying the Holding Register 66 T...

Page 28: ...de is not available for PFPs For further details see the related note in par 18 3 0 200 400 600 800 1000 1200 1400 Static pressure Pa 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Flow rate m3...

Page 29: ...for PC is also including an automatic procedure to calibrate the PID controller In many cases this software function can save the user from a lengthy manual calibration procedure For further informat...

Page 30: ...waiting for a new register 66 value The fan must stop waiting for a new register 66 value Temporary Setting Analog Signal The fan must follow the target corresponding to the analog value at the input...

Page 31: ...A modified fan with special pressure probes located on each inlet nozzle 2 A Pressure Transducer code K43198 located close to the fan and connected with pipes to the fan and with an electrical cable t...

Page 32: ...PFP PFP_500 265 PFP_560 334 PFP_630 PFP_710 PFP_800 For these values please contact Nicotra Gebhardt 11 2 How to calculate volume flow rate from pressure probe The following analytical equations show...

Page 33: ...to 0 and to a new value in short time If too long time passed and the fan runs at very low speed it is not possible to catch the speed the fan brakes and restarts 12 3 Flying start for 3 phase only Th...

Page 34: ...t a blocking alarm therefore the fan stops and auto restarts after few seconds 13 SOA LIMITATIONS The speed limits can be adjusted for the signal rescaling but also to limit the noise in the final app...

Page 35: ...1 Not active 12 Active Input type Enable function 0 Not active 1 Active 2 Active 3 Active 4 Active 5 Not active 6 Active 15 DERATING AND OVERHEATING PROTECTIONS When the temperature of the driver comp...

Page 36: ...rom 40 C to 50 C Higher temperatures could damage the motor winding or the performance could be significantly reduced WARNING WARNING 16 MASTER SLAVE MODE This feature is not available for PFPs 16 1 M...

Page 37: ...the stop bits can be chosen by modifying the Holding Register 48 and the possible choices are 0 No parity 2 Stop Bits default 1 Odd parity 1 Stop Bit 2 Even parity 1 Stop Bit Supported Function 03 Re...

Page 38: ...operating mode for setting the speed the airflow the slip and the PID reference It is not a physical register and it can be written but it is not possible to read its value The setting remains active...

Page 39: ...dim This register can be used to reset the fan by writing the value 1 on it This register automatically retun to value 0 after being reset The driver will reset any error condition and it will try to...

Page 40: ...to set the speed threshold low The register is active when the register 46 is set to the value 3 Allowed values 0 Speed Threshold High Default value 0 Holding Register 21 Fixed Speed setting RPM This...

Page 41: ...register 66 2 9 Modbus Fixed Asynchronous Emulation The emulation is set by modifying the register 30 2 10 Analog Ref PID Closed Control Loop The PID ref is set through the analog signal 11 Modbus Tem...

Page 42: ...bps not available using the opto insulated terminal block 576 corresponding to 57 6kbps not available using the opto insulated terminal block Holding Register 48 Modbus Stop Bits Adim Default 0 This r...

Page 43: ...used to set the speed threshold when the measured speed in the Input Register 3 overtakes the threshold value Allowed values 0 Max Speed Default value 0 Allowed values Functioning Indication mode Spe...

Page 44: ...module To know the rms value it must be divided by 2 Input Register 13 Motor Voltage 10 1 V This register indicates the peak value of the phase voltage module To know the rms line to line value it has...

Page 45: ...280 315 355 400 450 500 560 630 1 35kW 1 Phase 1 2 3 4 5 6 2 65kW 3 Phase 1 2 3 4 5 4kW 3 Phase 1 2 3 4 The Input Register 0 indicates the driver firmware version and the Input Register 1 indicates t...

Page 46: ...er 10 and Input Register 17 are indicated 19 2 Modbus registers Alarm description Alarm 1 Alarm 2 Description Actions Type 0 0 Default operation No Errors No Actions ALARM 1 1 0 Memory error Blocking...

Page 47: ...log 1 4 7 10 Signal set to 0V Fixed 2 6 9 12 Registers 21 39 30 and 50 set to 0 As conerns the Temporary Modbus mode it is necessary to reset the fan by setting the Holding Register 0 to value 1 inste...

Page 48: ...Rev 0 05 11 2020 OPERATING MANUAL OPERATING MANUAL EN EN 48 48 Regal Beloit Italy S p A Via Modena 18 24040 Ciserano BG ITALY Phone 39 035 873 111 Fax 39 035 884 319 www regalbeloit com...

Reviews: