background image

 

8- 

Please read carefully the 

instruction

, which includes important information about the 

installation, using and maintenance. 

SAFETY INSTRUCTIONS   

 

 

 

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also 

receive this instruction manual. 

 

Important: 

Damages caused by the disregard of this user manual are not subject to warranty. The dealer will 

not accept liability for any resulting defects or problems

 

Do not connect more than 7 items in series on the same power supply 

 

 

Unpack and check carefully that there is no transportation damage before using the unit. 

 

The unit is for indoor use only. Use only in a dry location. 

 

DO install and operate by qualified operator. 

 

DO NOT allow children to operate the fixture. 

 

Use safety chain when fixing the unit. Handle the unit by carrying its base instead of head only. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces.   

 

Be sure that no ventilation slots are blocked, otherwise the unit will be overheated. 

 

Before operating, ensure that the voltage and frequency of power supply match the power requirements of the unit. 

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

Maximum ambient temperature Ta: 40

. DO NOT operate it when the temperature is higher. 

 

DO NOT connect the device to any dimmer pack. 

 

During initial start-up some smoke or smell may arise. This is a normal process and does not necessarily mean that 

the device is defective, and it will decrease gradually within 15 minutes. 

 

Make sure there are no flammable materials close to the unit while operating to avoid fire hazard. 

 

Examine the power wires carefully, replace them immediately if there is any damage. 

 

Unit’s surface temperature may reach up to 85

. DO NOT touch the housing bare-handed during its operation, and 

allow about 15 minutes for cooling the unit down before replacing bulb or maintenance as it could be very hot. 

 

Avoid any inflammable liquids, water or metal objects entering the unit. Once it happens, cut off the mains power 

immediately. 

 

DO NOT operate in dirty or dusty environment, do clean fixtures regularly. 

 

DO NOT touch any wire during operation as there might be a hazard of electric shock. 

 

Avoid power wires together twist other cables. 

 

The minimum distance between light output and the illuminated surface must be more than 12 meters. 

 

Disconnect mains power before fuse/lamp replacement or servicing. 

 

Replace fuse only with the same type. 

 

In the event of serious operating problem, stop using the unit immediately.   

 

Never turn on and off the unit time after time. 

 

The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged. 

 

DO NOT open the unit as there are no user serviceable parts inside. 

 

Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. 

Please contact the nearest authorized technical assistance center if needed.   

 

Disconnect the mains power if the fixture is has not been used for a long time. 

 

DO use the original packing materials before transporting it again. 

 

Caution

 

 

To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture. 

 

Hot lamp explosion hazard. Do not open the unit within 15 minutes after switching off. 

 

DO replace the bulb once it is damaged, deformed or life-expired. 

 

DO NOT look directly at the light while the bulb is on. 

 

DO NOT start on the unit without bulb enclosure or when housing is damaged. 

Installation: 

The unit should be mounted by its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration 

and slipping while operating. The structure to which you are attaching the unit should be able to support 10 times the weight 

of the unit. Also always use a safety cable that can hold 12 times the weight of the unit when installing the fixture. 

The equipment must be fixed by professionals.   

Summary of Contents for UV PANEL 363 II

Page 1: ...UV PANEL 363 II Notice d utilisation...

Page 2: ...sont bien d gag es D branchez l appareil du secteur avant le remplacement d une pi ce ou avant toute r paration ou entretien Par s curit assurez vous qu aucun produit inflammable ne se trouve c t de l...

Page 3: ...X 1 ou 3 canaux Dimmer 0 100 Strobe Angle d ouverture 60 Alimentation AC 100 240C 50 60Hz Consommation 120W Max Dimensions 452 x 154 x 126 mm Poids 4 kg 1 prise d alimentation 2 touche menu 3 Ecran af...

Page 4: ...menu No Affichage Fonction Valeur Parametre 1 d001 Adresse DMX 001 512 Mode 1 canal 2 A001 Adresse DMX 001 512 Mode 3 canaux 3 U255 Variateur UV 000 255 Variateur manuel 4 F000 Stroboscope 010 255 Vi...

Page 5: ...nal Canal Fonction Parametre CH1 Variateur UV Eclairement de 0 100 Mode 3 canaux Canal Fonction Parametre CH1 Variateur UV Eclairement de 0 100 CH2 Stroboscope Strobe de lent rapide CH3 Mode Musical S...

Page 6: ...oints XLR sont plus utilis s que les 5 points XLR 3 points XLR Borne 1 La terre Borne 2 signal n gatif Borne 3 signal positif 5 points XLR Borne 1 La terre Borne 2 signal n gatif Borne 3 signal positi...

Page 7: ...reil avec un chiffon doux et utilisez un liquide de nettoyage pour vitres Il est toujours recommand d essuyer correctement toutes les pi ces de l appareil Nettoyez le syst me optique externe au moins...

Page 8: ...7 UV PANEL 363 II User guide...

Page 9: ...ut 15 minutes for cooling the unit down before replacing bulb or maintenance as it could be very hot Avoid any inflammable liquids water or metal objects entering the unit Once it happens cut off the...

Page 10: ...Consumption 120W Max Dimension 452 x 154 x 126 mm Weight 4 kg 1 prise d alimentation 2 MENU KEY 3 LCD Display 4 DMX signal MODE menu selection or return to previous menu UP press UP through the menu l...

Page 11: ...htness 4 F000 Strobe 010 255 UP DOWN change the speed 5 Soud Sound Active 050 255 SURE Master Slave Modes In DMX mode Lines 1 and 2 in the tab above The fixture is automatically set to SLAVE in other...

Page 12: ...power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR pl...

Page 13: ...side to high voltage cables that may cause damage or interference to DMX interface circuit C No response to the sound 1 Make sure the fixture does not receive DMX signal 2 Check microphone to see if i...