1. Safety Instruction  

 

 

WARNING 

 

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction 
booklet. 

 

Unpack and check carefully there is no transportation damage before using the unit. 

 

Before operating, ensure that the voltage and frequency of power supply match the power requirements of the unit.  

 

It’s important to ground the yellow/green conductor to earth in order to avoid electric shock. 

 

Suitable for both indoor & outdoor use. 

 

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces.  

 

Disconnect mains power before replacement or servicing.  

 

Make sure there is no flammable materials close to the unit while operating as it is fire hazard.  

 

Use safety cable when fixes this unit under ceiling or on the truss. 

 

Maximum ambient temperature is ta: 40

. Don’t operate it where the temperature is higher than this. 

 

Unit surface temperature may reach up to 60

. Don’t touch the housing bare-hand during its operation. Turn off the power and allow 

about 15 minutes for the unit to cool down before replacing or serving. 

 

In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by 
unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the 
same type spare parts. 

 

Do not touch any wire during operation as high voltage might be causing electric shock.

 

 

Do not open the unit within five minutes after switching off. 

 

Make sure that the housing is firmly closed and all screws are tightly fastened when operate. 

 

Caution 

There are no user serviceable parts inside the unit. Do not open the housing or attempt any repair yourself. In the unlikely event your 
unit may require service, please contact your nearest dealer. 

Installation 

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping 
while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 20 
times of the unit. 

 

 2. Technical Specification  

IP WASH 240 

LED PANEL 24X10W RGBW FC IP with barn doors 

 
This product is designed for outdoor use. Suitable applications include wash or effect lighting for architectural, stage or nightclub 
applications. 
This product can also be installed for use in signage and advertising using the dynamic functions available with DMX512 controller. This 
product can be operated as a single unit or in multiple units for large applications.  
 

* Light source: 24X10W (RGBW 4 in 1 LED) 
 * DMX channel: 9 
 * Control: Auto, DMX, Master/Slave 
 * IP rating: 66 
 * 16 chases 
 * Beam angle: 35°  
 * Lifespan: 50 000 H 
 * Lumens: 6600 lux @ 2M 
 * Voltage: AC100-240V, 50/60Hz 
 * Size: 670 x 105 x 230 mm 
 * Net weight: 7,9kg 

 

 

Please read carefully the instruction which includes important information 
about the installation, usage and maintenance. 

Summary of Contents for IP WASH 240

Page 1: ...IP WASH 240 Manuel d utilisation Nous vous recommandons de lire attentivement le manuel avant toute utilisation...

Page 2: ...au bout de quelques minutes Par s curit assurez vous qu aucun produit inflammable ne se trouve c t de l appareil lors de l utilisation Ne pas toucher les fils pendant que l appareil fonctionne afin d...

Page 3: ...con u pour une utilisation ext rieure Il convient pour des installations wash effets lumineux pour l architecture la sc ne ou des clubs de nuit Ce produit peut galement tre install pour de la signali...

Page 4: ...mmer de rapide lent 7 Strobe 0 255 Effet du strobe de lent rapide 8 Mode auto 0 99 Couleur macro 100 119 3 changements de couleurs 120 139 7 changements de couleurs 140 159 7 changements de couleurs l...

Page 5: ...t quip e d un bouchon de terminaison R sistance 120 ohm 1 4W entre les pin 2 DMX et pin 3 DMX 5 MAINTENANCE Le nettoyage de l appareil syst me d optique externe doit tre fait r guli rement pour que le...

Page 6: ...IP WASH 240 User Manual For safety purpose please read this manual carefully before your operation...

Page 7: ...Always use the same type spare parts Do not touch any wire during operation as high voltage might be causing electric shock Do not open the unit within five minutes after switching off Make sure that...

Page 8: ...g DMX CHANNELS Channel Function Value Description 1 Dimmer 0 255 0 255 2 Red 0 255 0 255 3 Green 0 255 0 255 4 Blue 0 255 0 255 5 White 0 255 0 255 6 Dimming speed 0 255 Dimming speed from fast to slo...

Page 9: ...MENU...

Page 10: ...es be connected well or not Check whether the DMX cable has to be terminated with a terminator to reduce signal errors If not please Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into...