background image

c.  SAFETY INTRUCTIONS FOR LASERS 

According to EN/IEC 60825-1 regulations, this laser is classified under 3B class. Direct eye exposure can be dangerous 

 

   

DANGER: LASER RADIATION! 

UNIT UNDER 3 B CLASS   

AVOID DIRECT EYE EXPOSURE. LASER RADAITION CAN CAUSE EYE DAMAGE AND/OR SKIN DAMAGE 

AVOID EXPOSTION TO LASER RADIATION 

ALL PROTECTIVE MEASURES MUST BE APPLIED FOR MAKING THE USE OF LASERS SAFE 

 

This product is a so-called show laser emitting radiation with a wavelength spectrum and producing lasers for shows. 

 

A laser (Light Amplification by Stimulated Emission of Radiation) is a device that emits light trough a process of optical amplification and 

produce electromagnetic radiation of different wavelengths due to the controlled stimulated emissions process. 

In addition to the secondary effects due to the operating laser conditions, fire risks or burning hazards, the most important danger comes 

from the light source. The damages on eyes depend on the laser wavelengths specifications, the eye distance and the elements  linked 

to the eye specifications. This danger is amplifies if the laser beams are focused to tiny spots; that is why the effects on eyes are even 

more important while using lasers. 

3B class can be dangerous under specific conditions 

4 class should be ruled under strict safety warnings. 

 

INSTALLATION OF THE UNIT 

The units from 3B class and 4 class, exclusively used in open air, should be installed by experienced and qualified professionals, trained 

to the specific risks of lasers and should handle a user manual. 

The area reserved for the public should be limited up to 3 meters above the ground and to 2.5 meters from the public. This zone should 

be indicated and marked on the ground. In this area, it is not possible to make “pencil beams” (through the output being a narrow beam 

which  is  diffraction-limited) in the  direction  of  people,  whatever  the  laser  class  is,  except  if  a  determined  area  has  been  defined  of 4 

meters radius from the public and visibly marked on the ground. 

Only laser beams of wavelengths divergence concentrated their power at a large distance are authorized. 

 

OPERATION OF THE UNIT 

The use of lasers is out of the reach of people when considering: 

That the unit is situated at 3 meters above the floor at least 

That a safety area is defined within 5 meters radius 

The user takes the responsibility that the units under 3B class or 4 class are mounted by a qualified technician and experienced 

to the risks of lasers. This technician must stay around during all the time the lasers work and he must be able to stop the units 

in case some technical problems would occur. While the installation is on, the technician should wear protective glasses. 

 

Please remind the following remarks: 

Laser light is different from any other light source with which you may be familiar. The light from this product can potentially 

cause eye injury if not set up and used properly.   

Laser light is thousands of times more concentrated than light from any other kind of light source. This concentration can cause 

instant eye injuries, by burning the retina. Even if you can not feel heat from a laser beam, it can still injure or blind you or the 

audience. 

Never look at the laser aperture or laser beams. 

Do not direct the laser beam to people. 

Do not leave the device running without the presence of qualified professionals. 

 

EXPELEC can not liable for damages caused by incorrect installations and unskilled operation. 

 

 

 

Summary of Contents for GLAM LASER

Page 1: ...GLAM LASER PROFESSIONAL LASER USER MANUAL Thank you for using our products For the sake of safety and better operation of this product please read this manual carefully before using and operating it...

Page 2: ...the unit to rain or moisture The working temperature of the unit is from 18 to 30 C Do not use it at higher temperature Do not switch on and off many times to avoid reducing the life duration of the f...

Page 3: ...nd to 2 5 meters from the public This zone should be indicated and marked on the ground In this area it is not possible to make pencil beams through the output being a narrow beam which is diffraction...

Page 4: ...to control in DMX mode The unit has blackout function The unit will shut off if no DMX signal Design according to performance and security Master Slave mode DMX 512 mode and PC control mode will shut...

Page 5: ...8 255 Auto rolling CH8 Rotation 0 127 Manual rotation 128 191 Auto clockwise rotation 192 255 Auto counter clockwise rotation CH9 Zoom 0 85 Auto zoom 86 170 Auto zoom 171 255 Manual zoom CH10 Pattern...

Page 6: ...to react to the sound of music 1 Place the device in a suitable and stable position 2 Set the dipswitch to select AUTO or Sound active mode 3 Turn on the unit The unit resets then it begins to work 4...

Page 7: ...ve indicator does not lit up and the light beam does not work a The sound is too low Increase the volume of music or sound sensitivity b Check if the device is in slave mode then set up in master mode...

Page 8: ......

Reviews: