5
RS-485 communication: the equipment has 4 independent channels (a, b, c, d)
for RS-485 input, with individual integrated circuit. Used for UHF Antennas and
dedicated Biometric Scanners.
F) Selecting the Operation Mode (4-way Dip Switch)
DIP 1
DIP 2
DIP 3
DIP 4
FUNCTION
X
X
X
OFF
CAN baud rate 125 kbps*
X
X
X
ON
CAN baud rate 20 kbps
OFF
OFF
OFF
X
REC TX Mode*
ON
OFF
OFF
X
REC CTWB Mode
OFF
ON
OFF
X
PASSIVE TAG Mode
ON
ON
OFF
X
REC TX+TP Mode
OFF
OFF
ON
X
REC TX+CTWB Mode
ON
OFF
ON
X
ACTIVE TAG Mode
OFF
ON
ON
X
*Spare*
ON
ON
ON
X
IO Module
CAN baud rate:
can assume the values of 125 kbps (standard and recommen
-
ded) and 20 kbps. For long communication lines between the MG 3000 Module
and the Receiver, we suggest that a low baud rate and adequate cabling are
adopted. However, this selection must also be made on all equipment on the line
(MG 3000 Module and other Receivers).
G) Buzzer
Buzzer emitting audible alerts.
H) BOOTLOADER key
Key to perform the “bootloader” function.
I) USB Host Port
USB-A input to rewrite the equipment’s firmware, for possible corrections and
operational improvements.
Note:
IN ORDER TO PERFORM THIS PROCEDURE IT IS NECESSARY TO
CONTACT THE TECHNICAL SUPPORT, OBTAINING THE DUE INSTRUC
-
TIONS.
J) Programming Keys
UP (increase), DOWN (decrease), FWD (forward) and PROG (programing).
- ENGLISH -
61