background image

17

EN

19

PROTECTION OF PROGRAMMED 
FUNCTION SETTINGS

[with O-Box / O-View] 

– This function enables the user to

protect all programmed functions on the receiver, also dis-
abling functionality of the key and relative led. The function is
enabled by entering a 

password

on the receiver, i.e. a maxi-

mum of 10 digits, as set by the installer.
When the function is enabled, before programming and main-
tenance of the receiver, the special 

password

must be entered

on the programming unit to unlock the receiver.

DISPOSAL OF THE PRODUCT

This product constitutes an integral part of the automa-
tion system, therefore it must be disposed of along with it.

As in installation, also at the end of product lifetime, the disas-
sembly and scrapping operations must be performed by qual-
ified personnel. 
This product is made up of different types of material, some of
which can be recycled while others must be disposed of. Seek
information on the recycling and disposal systems envisaged
by the local regulations in your area for this product category.

Caution!

– some parts of the product may contain pollutant or

hazardous substances which, if disposed of into the environ-
ment, may cause serious damage to the environment or phys-
ical health.

As indicated by the symbol on the left,
disposal of this product in domestic
waste is strictly prohibited. Separate the
waste into categories for disposal,
according to the methods envisaged by
current legislation in your area, or return
the product to the retailer when purchas-
ing a new version.

Caution!

– Local legislation may envisage serious fines in the

event of abusive disposal of this product.

www.ApolloGateOpeners.com  |  (800) 878-7829  |  [email protected]

Summary of Contents for NICEONE OX2 SERIES

Page 1: ...NiceOne Europe 0682 Installation and use instructions and warnings Receiver OXI family OX2 family www ApolloGateOpeners com 800 878 7829 Sales ApolloGateOpeners com...

Page 2: ...2 EN EN Models with SM type connection EN Models with universal type connection www ApolloGateOpeners com 800 878 7829 Sales ApolloGateOpeners com...

Page 3: ...s are available with the specifications as stated in the table below 1 1 The NiceOpera system The receivers in the series NiceOne are part of the Nice Opera system This system has been designed to sim...

Page 4: ...in the receiver unless further protection meas ures are adopted such as the use of a security password For models with SM type connection These models can be used exclusively with the control units fi...

Page 5: ...installed connecting it to the specific terminals on the control unit For models with universal type connection Power supply selection These models are connected to the control unit by means of a 6 co...

Page 6: ...nge to NC normally closed type contact proceed as follows 01 Disconnect the receiver from the power supply 02 Open the box of the receiver by first raising the smaller section of the cover fig 4 a and...

Page 7: ...7 EN 4 a b 5 www ApolloGateOpeners com 800 878 7829 Sales ApolloGateOpeners com...

Page 8: ...tion to the receiver only for models with univer sal type connection Open the receiver by first raising the smaller section of the cover fig 4 a and disconnect the aerial supplied then connect the cab...

Page 9: ...most suited to your specific application 5 TRANSMITTER MEMORISATION PROCEDURE Mode I AND Mode II Each control unit has a set number of commands that can be activated according to the type of receiver...

Page 10: ...lashes repeated at regular intervals 03 on the transmitter within 10 seconds Press and hold the selected key for memorisation until the led on the receiv er emits the first of 3 flashes memorisation c...

Page 11: ...an OLD transmitter previously memorised in Mode I or in Mode II and operative is required The procedure enables the NEW transmitter to receive the settings of the OLD version WARNINGS Use only one of...

Page 12: ...by programming the function in paragraph 10 8 TOTAL RECEIVER MEMORY DELETION All transmitters memorised can be deleted from the receiver memory or all data present in the latter can be deleted as fol...

Page 13: ...switch on by pressing the receiver key until the relative led has completed the sig nals indicating the type of code stored in the memory see paragraph 5 and the procedure is activated indicat ed by 2...

Page 14: ...rocedure enables transmitter memorisation from any distance even far from the installation site for exam ple from the installer s office fig 9 WARNING The settings described in this chapter require us...

Page 15: ...smitter can be disabled by simply updating the priority level of the new transmitter with the next highest value On first use of the transmitter the receiver memorises the new priority level received...

Page 16: ...x program ming unit while use of the groups for example in a set time band is managed by means of the O View programming unit 15 ENABLING or disabling THE REPEATER FUNCTION Function available only on...

Page 17: ...be performed by qual ified personnel This product is made up of different types of material some of which can be recycled while others must be disposed of Seek information on the recycling and disposa...

Page 18: ...ut electric jumper 24 V standard Limits from 18 to 28 V direct or alternating With electric jumper 12 V standard Limits from 10 to 18 V direct or alternating Absorption on standby 10 mA at 24 Vac Abso...

Page 19: ...specifications The range of the transmitters and reception capacity of the receivers is strongly influenced by other devices for exam ple alarms radio headphones etc operating in the zone at the same...

Page 20: ...uring programming indicates that the code has been re synchronised 4 5 Output in Mode II not managed on control unit 5 5 During deletion procedure indicates that the code has been deleted 5 5 Certific...

Page 21: ...Rustign 31046 Oderzo TV Italy Type Receiver and receiver transmitter for remote control of automations for doors gates shutters awnings rolling shutters and similar applications Models OXI OXIT OXIFM...

Page 22: ...Rustign 31046 Oderzo TV Italy Type Receiver and receiver transmitter for remote control of automations for doors gates shutters awnings rolling shutters and similar applications Models OX2 OX2T OX2FM...