Nice Moonbus Instructions And Warnings For The Fitter Download Page 3

GB

3

LED “L”

Off

3 quick flashes and a
second’s pause
Very slow flashing

Slow flashing
Quick flashing

Very quick flashing

Always ON

Status

The photocell is either not
powered or is faulty
Device not recognised by the
control unit
The TX transmits regularly
The RX receives a perfect signal.
The RX receives a fair signal
The RX receives a poor signal

The RX receives a very poor
signal
The RX does not receive any
signal at all

Action

Make sure the voltage for the photocell terminals is approximately 8-12
Vdc. If the voltage is correct, the photocell is probably broken. 
Repeat the learning procedure on the control unit. Make sure that all the
photocell pairs have different addresses
Normal operation

Normal operation
Normal operation. However, it is best to check the TX-RX alignment and
make sure the glasses are clean
It is at the very limit of normal operation. Check the TX-RX alignment
and make sure the glasses are clean.
Make sure that the LED on TX flashes once slowly. Check to see if there
is an obstacle between TX and RX. Check the TX-RX alignment

Table 2

After the recognition phase, check that the LED on the photocell starts flashing (both on TX and RX). Check Table 2 for the state of the photocell based on the
way LED “L” flashes.

5) Testing and checking operation

Warning:

After you have added or removed any photocells, the automation

system must be tested again according to the directions contained in the
installation manual. 

To check the photocells and make sure that there is no interference with oth-
er devices, pass a 5 cm diameter, 30 cm long cylinder on the optical axis, first
near TX, then near RX and finally at the mid-point between them (shown in
Figure 9) and make sure that in all these cases the device is triggered, switch-
ing from the active to the alarm status and vice-versa; finally, that it causes the

intended action in the control unit, for example that it causes the reversal of
the movement during the closing manoeuvre.

To check the photocells as an optical presence sensor (type D),according to
the EN 12445 standard, is performed with the 700x300x200mm test paral-
lelepiped with 3 opaque black sides and 3 polished white sides or mirrored as
shown in figure 10 following that stipulated by chapter 7 of the EN
12445:2000 standard (or enclosure A of prEN 12445:2005).

L

The photocells do not require any special maintenance work. However, it is nec-
essary to check them at least once every six months in order to evaluate their con-
dition (presence of damp, oxides, etc.). The outer covering and lenses must be
cleaned, then testing carried out again, as described in the previous paragraph.

The photocells have been studied and designed in order that that they will
operate in normal conditions for at least 10 years. It is, therefore, necessary
to increase the frequency of the maintenance work carried out on the said
photocells after this period of time has elapsed. 

6) Maintenance

6.1) Disposal 

As for the installation, the disposal of the product at the end of its effective life,
must be performed by qualified personnel. This product is made of various
types of material, some of which can be recycled while others must be dis-
posed of. Enquire about the recycling or disposal systems available for this
product category in compliance with regulations locally in force.

Warning:

some parts of the product may contain polluting or hazardous sub-

stances that, if incorrectly disposed of, could have a damaging effect on the
environment or on the health of individuals.

As indicated by the symbol in figure 11, this product
must not be disposed of in household waste. Per-
form “separated collection” for disposal in compli-
ance with regulations locally in force, or return the
product to the manufacturer when purchasing a
replacement. 

Heavy fines may be imposed by local laws for the illegal disposal of this prod-
uct.

7) Technical characteristics

Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics at any time without prior notice. In any case, the man-
ufacturer guarantees their functionality and fitness for the intended purposes. Note: all technical specifications refer to a temperature of 20°C. 

Product type

Detector for gate and door automation systems (type D according to EN standard 12453), consisting in a “TX”
transmitter and “RX” receiver.

Technology employed

TX-RX direct optical interpolation with modulated infrared ray.

Power supply/output

The device can only be connected to “BlueBus” networks, from which it receives its power supply and sends
output signals.

Absorbed power

1 “BlueBus” unit.

Detection capacity

Opaque objects (larger than 50 mm) located on the optical axis between TX and RX, which move more
slowly than 1.6m/s.

TX transmission angle

20° +/- 25%

RX reception angle

Approximately 20°.

Adjustability of the MOFOB photocell

Approximately 30° along the horizontal and vertical axes. 

Useful range

Up to 15m for a maximum TX-RX misalignment of ± 5° (the device can detect and signal an obstacle even in
particularly bad weather conditions).

Maximum range (under optimum conditions) 

Up to 30m for a maximum TX-RX misalignment of ± 5°. 

Maximum cable length

Up to 50 m.

Addressing possibility

Up to 7 detectors with the protection function, and 2 with the opening command function. 
The automatic synchronism prevents any interference among the various detectors.

Use in acid, saline or potentially

No

explosive atmospheres
Mounting Vertically 

wall-mounted

Protection class for casing

IP55

Operating temperature 

20 ÷55°C

Dimensions / weight

for MOFB     69 x 78 h 25mm / 50g
for MOFOB   69 x 78 h 37mm / 75g

11