Nice CO Alarm-Control Instructions And Warnings For Installation And Use Download Page 6

8

VISUAL INDICATIONS & ACOUSTIC SIGNALS

CO Alarm-Control is equipped with a LED diode and a buzzer, signalling menu position and status of the device.

Table A1 - Device status indications

4 x BEEP 

every 5s

4 x RED BLINK every 

5s

Detected presence 

of carbon monoxide 

which can kill you!

1. Open the windows

2. Move to fresh air!

3. Contact emergency  

     services

1 x BEEP

1 x YELLOW BLINK 

every 30s

Low battery level

Replace the battery

1 x BEEP 

every 30s

Sensor error (does not 

detect carbon mon-

oxide)

Reset the device,  

replace if no effect

2 x BEEP

2 x CYAN BLINK every 

30s

End of lifespan

Reset the device,  

replace if no effect

3 x BEEP 

every 30s

1 x BLUE BLINK every 

30s

Heat alarm

Be cautious of fire

1 x BEEP

1 x WHITE BLINK

Tamper alarm

Check the housing

1 x GREEN BLINK after 

button press

Device powered

1 x BEEP

1 x GREEN BLINK after 

powering

Added to Z-Wave

1 x BEEP

1 x RED BLINK  

after powering

Not added to Z-Wave

1 x BEEP

1 x MAGENTA BLINK 

every 10min

Out of range

Check the Z-Wave range

CYAN BLINKING

Firmware update

Wait for completion

9

OPERATING THE DEVICE

Using batteries other than specified may result in explosion. Dispose of properly, observing environmental protection rules.

Use only type of battery specified in this manual and keep proper polarity!

CO Alarm-Control can be powered with CR123A (included) battery. Estimated battery life with device on default settings is 3 years (tested with 

Panasonic Industrial Lithium).

9.1 - Checking battery level

CO Alarm-Control automatically warns about low battery with one yellow blink and a short beep, when battery level is low.

9.2 - Replacing the battery

In order to replace the battery:
1.  Remove the device from the cover by turning it counter-clockwise.
2.  Pull the paper strip to take out the battery.
3.  Press and hold the button for at least one second.
4.  Insert a new CR123A battery observing the polarities shown inside.
5.  Attach the device to its cover by turning it clockwise and perform the battery test described above.

10

ASSOCIATIONS

Association (linking devices) - 

direct control of other devices within the Z-Wave system network e.g. Dimmer, Relay Switch, Roller Shutter 

or scene (may be controlled only through a Z-Wave controller). 
Association allows direct transfer of control commands between devices, is performed without participation of the main controller and re-

quires associated device to be in direct range.

Summary of Contents for CO Alarm-Control

Page 1: ...EN Instructions and warnings for installation and use CO and temperature sensor CO Alarm Control Nice...

Page 2: ...these symptoms even in healthy people It can also cause sleepiness vision problems including blurred vision ringing in the ears aching arms and legs irregular breathing fatigue and confusion At very...

Page 3: ...ting Z Wave network To add the device to the Z Wave network manually 1 Place the device within direct range of the Z Wave controller 2 Set the main Z Wave controller in security non security adding mo...

Page 4: ...e ceiling level The device should be installed on the wall at least 30 cm 1 ft away from the corners The device should not be installed in a bathroom next to heat sources within range of kids obstruct...

Page 5: ...e self test procedure does not result in emitting sound and red light signal replace the device 1 Press and hold the button 2 The LED indicator will glow white and you will hear a short beep 3 Release...

Page 6: ...than specified may result in explosion Dispose of properly observing environmental protection rules Use only type of battery specified in this manual and keep proper polarity CO Alarm Control can be...

Page 7: ...me cases system response may be delayed Notification report The device uses Notification Command Class to report different events to 1st association group Lifeline Table A2 Notification reporting Noti...

Page 8: ...0 Parameter size 1 byte Parameter 7 Associations in Z Wave network security mode Description Parameter defines how commands are sent in specified association groups as secure or non secure Parameter...

Page 9: ...Parameter size 2 bytes Parameter 17 CO Level required for sending BASIC OFF command to 4th association group Description This parameter defines the level of CO concentration below which falling will...

Page 10: ...vel which exceeding will result in sending a new value to the main Z Wave controller according to parameter 25 settings Adjusting the value allows to get the accurate data in case of danger and helps...

Page 11: ...el 85 dBA at 3 meters 10 feet Operating temperature 0 50 C Operating humidity 10 95 RH without condensation Dimensions d x h 65 x 28 mm Radio frequency of individual device must be same as your Z Wave...

Page 12: ...ces which if disposed of into the environment may cause serious damage to the environment or physical health As indicated by the symbol alongside disposal of this product in domestic waste is strictly...

Page 13: ...www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com IS0860A00EN_15 03 2022...

Reviews: