Nice BiDi-Shutter Instructions And Warnings For Installation And Use Download Page 2

1

WARNINGS AND GENERAL PRECAUTIONS

• 

CAUTION! – This manual contains important instructions and warnings for personal safety.

 Carefully read all parts of this manual. If 

in doubt, suspend installation immediately and contact the Nice Technical Assistance.

• 

CAUTION! – Important instructions: keep this manual in a safe place to enable future product maintenance and disposal pro-

cedures.

• 

CAUTION! – All installation and connection operations must be performed exclusively by suitably qualified and skilled person-

nel with the unit disconnected from the mains power supply.

• 

CAUTION! – Any use other than that specified herein or in environmental conditions other than those stated in this manual is 

to be considered improper and is strictly forbidden!

•  This product may only be used indoors or protected from weather conditions by control unit’s housing.
•  The product’s packaging materials must be disposed of in full compliance with local regulations.
•  Do not open the device protection housing as it contains non-serviceable electrical circuits.
•  Never apply modifications to any part of the device. Operations other than those specified may only cause malfunctions. The manufacturer 

declines all liability for damage caused by makeshift modifications to the product.

•  Never place the device near to sources of heat and never expose to naked flames. These actions may damage the product and cause 

malfunctions.

•  This product is not intended for use by people (including children) with reduced physical, sensory or mental capabilities or who lack experi-

ence and knowledge, unless they have been given supervision or instruction concerning the use of the product by a person responsible for 

their safety.

•  Make sure that children do not play with the product.
•  Check the warnings in the instruction manual for the motor that the product is connected to.
•  Handle the product with care, being sure not to crush, knock or drop it in order to avoid damage.

2

PRODUCT DESCRIPTION

The BiDi-Shutter control unit enables the control of a single-phase asynchronous motor, mains pow-

ered, with connection types: Down, Common, Up, used for the automation of awnings, rolling shutters, 

Venetian blinds and similar.
The BiDi-Shutter control unit incorporates a radio transceiver that operates at the frequency of 433.92 

MHz with rolling code technology to guarantee optimal safety levels.
Each control unit can memorise up to 30 mono or bidirectional transmitters in the series ERA, ERGO, 

FLOR, NICEWAY and VERY, which enable the remote control of the unit. 
In the 30 transmitters, climatic radio sensors can be memorised, for the automatic control of the control 

unit according to weather conditions.
The control unit is equipped with two inputs for controlling the unit by means of external pushbuttons.
Memorisation and programming is possible via the programming pushbutton (figure 1) on the BiDi-Shutter. 
The user is guided through the various phases by means of LED signals.
The control unit is equipped with overload, and overheating protection, which will disable the relays to 

prevent damage to the circuit. 

3

INSTALLATION

• 

The product is subject to hazardous electric voltages 

• 

The installation of the BiDi-Shutter and automations must be performed exclusively by technically qualified personnel, in 

observance of current legislation and standards, and according to these instructions. All connections must be made with 

the system disconnected from the power supply.

• 

The BiDi-Shutter control unit has been especially designed for insertion in a junction box or wall box; its housing does not 

feature any protection against water and only basic protection against contact with solid parts. Never place the BiDi-Shutter 

in inadequately protected environments. 

• 

Never open or perforate the BiDi-Shutter housing, this is subject to hazardous electric voltages!

3.1 - Preliminary checks

• 

The power supply line must be protected by suitable magneto-thermal (compliant with IEC/EN 60898-1 standard, rated up to 16A) and 

residual-current circuit breakers.

• 

A disconnection device must be inserted in the power supply line from the electrical mains (the distance between the contacts must be at 

least 3mm with an overvoltage category of III) or equivalent system, for example an outlet and relative plug. If the disconnection device for 

the power supply is not mounted near the automation, it must have a locking system to prevent unintentional, unauthorized connection.

Programming 

pushbutton

LED

1

Summary of Contents for BiDi-Shutter

Page 1: ...EN Instructions and warnings for installation and use Interior bidirectional interface for tubular motor BiDi Shutter Nice ...

Page 2: ...awnings rolling shutters Venetian blinds and similar The BiDi Shutter control unit incorporates a radio transceiver that operates at the frequency of 433 92 MHz with rolling code technology to guarantee optimal safety levels Each control unit can memorise up to 30 mono or bidirectional transmitters in the series ERA ERGO FLOR NICEWAY and VERY which enable the remote control of the unit In the 30 t...

Page 3: ...n connected to S1 is responsible for Up movement and the pushbutton connected to S2 is responsible for Down movement The pushbuttons carry mains voltage and must therefore be adequately protected and insulated 4 MEMORISING TRANSMITTERS This chapter describes the memorisation procedures in Mode I used to control a single automation with the 3 keys of the transmitters and Mode II used to control an ...

Page 4: ...e LED illuminates with red color 1st position 03 Within 10 seconds Monodirectional transmitters press and hold any key of the transmitter to be memorized for at least 3 seconds Bidirectional transmitters press any key of the transmitter to be memorized MONO 3s BIDI 04 If the memorisation procedure is successful the LED emits 3 red flashes 05 Repeat steps 3 and 4 to acquire all the remotes 06 After...

Page 5: ...irectional transmitters press and hold the required key of the transmitter to be memo rized for at least 3 seconds Bidirectional transmitters press the required key of the transmitter to be memorized MONO 3s BIDI 06 If the memorisation procedure is successful the LED emits 3 orange flashes 07 Repeat steps 5 and 6 to acquire all the remotes with the same command 08 Repeat steps 3 to 6 to acquire al...

Page 6: ... as described below Perform manual calibration only when automatic doesn t work Table A9 Manual calibration Example 01 Press and hold the programming pushbutton fig 1 02 Release the programming pushbutton fig 1 when the LED illuminates with blue color 3rd position 03 Press key s or first channel of the transmitter to start calibration 04 Device will start Up maneuver 05 Press key n or second chann...

Page 7: ...t to the specified position range Table A14 Setting a virtual limit switch Example 01 Bring the shutter blind awning at your desired position virtual limit switch 02 Press and hold the programming pushbutton 03 Release the programming pushbutton when the LED illuminates with blue color 3rd position 04 Press key t or third channel of the transmitter If the LED will confirm with one blue flash the p...

Page 8: ... as described below Table A16 Setting Venetian blinds behavior Example 01 Press and hold the programming pushbutton fig 1 02 Release the programming pushbutton fig 1 when the LED illuminates with cyan color 7th position 03 Press key s or first channel of the transmitter toggle the setting the LED informs about current setting Fixed cyan Venetian blinds control enabled Turned off Venetian blinds co...

Page 9: ...to confirm the correct removal 05 After 10 seconds that the device doesn t receive any signal the programming procedure concludes auto matically 5 8 Factory reset If the control unit needs to be reset to the factory settings all transmitters and setting will be deleted proceed as described below Table A20 Restoring to factory defaults Example 01 Press and hold the programming pushbutton fig 1 02 R...

Page 10: ...0 including climatic sensors Transceiver range Estimated at 150 m in open space and 20 m inside buildings Max transmit power 10 dBm The transceiver range is strongly influenced by other devices operating at the same frequency with continuous transmission such as alarms and radio headphones which interfere with the control unit transceiver 8 PRODUCT DISPOSAL This product is an integral part of the ...

Page 11: ...www niceforyou com Nice SpA Oderzo TV Italia info niceforyou com code ...