![Nice HySecurity SwingSmart DC Series Installation And Programming Manual Download Page 94](http://html1.mh-extra.com/html/nice-hysecurity/swingsmart-dc-series/swingsmart-dc-series_installation-and-programming-manual_1687275094.webp)
GENERAL MAINTENANCE
SMART TOUCH ANALYZE AND RETRIEVE
TOOL
HySecurity provides Smart Touch Analyze and
Retrieve Tool (START) software to help HySecurity
gate operator users and installers conduct the
following field service activities:
z
Configure installer and user menu settings
z
View the operator history (event) log
z
Display monitored inputs for operator
diagnostics
z
Load Smart DC Controller (SDC) operator code
With START software loaded on your laptop
computer, you have an invaluable management
tool for all HySecurity operators. Either the USB
port or the RS-232 serial port, found on the Smart
DC Controller (see
), allows you to
download system diagnostics and upload system
configurations using the START software. The
free START software is conveniently located on
the www.hysecurity.com website. Instructions for
downloading START are found on the website,
as well.
What You Need
z
Standard USB 2.0 A-B communications cable.
If you are using the HySecurity RS-232 to USB
adapter, be sure to install the USB driver in your
laptop.
z
Laptop computer with Windows PC operating
system (XP, Vista, or Windows 7/8/8.1/10)
z
Minimum 128MB of RAM
z
Minimum 5MB of hard drive disk space
z
VGA graphics card (minimum resolution of 800
x 600)
Installing START Software
Read the START User Manual, and then take the
following steps to download START software:
1.
Bring up your web browser and type in http://
www.hysecurity.com in the command line.
2.
Click Technical Support (left column) on the
HySecurity home page.
3.
Enter your user name and password. If you do
not have a user name, register as an online
member.
4.
Click to Download: S.T.A.R.T. software for
Smart Touch and Smart DC.
5.
Read the End User License Agreement and,
if you agree to the terms, click on, I accept
(bottom of the page).
6.
Click RUN. A setup window appears.
7.
Follow the step-by-step instructions to
complete the installation.
8.
When the download is complete, log out of the
HySecurity website. Shortcuts for the START
and Smart DC Controller History Logs appear
on your laptop’s desktop.
Figure 59. RS-232 and USB Connection
NOTICE
If the operating system on your laptop is
VISTA or Windows 7, you must first disable the
"User Account Control Settings," refer to the
procedure in
"Setting User Account Controls"
on page 95 and then continue to step 9.
STOP BUTTON
OPEN BUTTON
CLOSE BUTTON
REMOTE OPEN AND
RADIO CONTROL
OPEN/CLOSE
1
OPEN PARTIAL
INTERLOCK OPEN
TIME CLOCK OPEN
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
VEHICLE DETECTOR
SHADOW/RESET
VEHICLE DETECTOR
EDGE SENSOR
PHOTO EYE POWER
24 VOLTS COMMON
PHOTO EYE POWER
DO NOT USE
PHOTO EYE
OPEN DIRECTION
DO NOT USE
PHOTO EYE
CLOSE DIRECTION
DO NOT USE
CHARGER
AC LOSS
EMERG CLOSE
FIRE DEPT OPEN
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
Smart Touch Controller
LIMIT
DUAL GATE
RADIO OPTIONS
DRIVE
POWER
RS485
MO
TOR
USER 1
USER 2
USER 3
VEHI
CLE DETE
CT
OR
VEHI
CLE DETE
CT
OR
VEHI
CLE DETE
CT
OR
STOP
/B
UZZER
FREE
EXIT
INSIDE
OB
STR
OUT
SIDE
OB
STR
SHADO
W
RE
SET
WIE
GAND
Hy
Security
COM
NO
MX000585
VERSION
S/N
RS232
DISPLA
Y
VEHI
CLE DETE
CT
OR
COM
COM
A
B
RPM
COM
OPEN
EDGE
+24V
+24V
STATUS
LED
Power Connector
LOCK INTERLOCK
Connect to RS-232 with
a HySecurity adapter.
RS-485
COMMUNICATION
USB
SwingSmart DC Programming and Operations
MX3640-01 Rev. E ©2020
94