2.2) Typical System
Figure 2 shows a typical system for automating a sliding gate using NiceHansa Robus
1
Key-operated selector switch
6
“Open” stop bracket
11
“Closed” stop bracket
2
Photocells on post
7
Rack
12
Secondary movable edge (optional)
3
Photocells
8
Secondary fixed edge (optional)
13
Radio-transmitter
4
Main fixed edge (optional)
9
Flashing light with incorporated aerial
14
Circuit breaker
5
Main movable edge
10
NiceHansa Robus
2
4
3
3
8
10
2
6
11
7
9
13
12
5
1
E
C
C
F
D
F
14
A
B
2.3) List of cables
Figure 2 shows the cables needed for the connection of the devices in
a typical installation; table 5 shows the cable characteristics.
The cables used must be suitable for the type of installation;
for example, an H03VV-F type cable is recommended for indoor
applications, while H07RN-F is suitable for outdoor applica-
tions.
!
Note 1:
power supply cable longer than 30 m may be used provided it has a larger gauge, e.g. 3x2,5mm
2
, and that a safety grounding system
is provided near the automation unit.
Note 2:
If the “BLUEBUS” cable is longer than 30 m, up to 50 m, a 2x1mm
2
cable is needed.
Note 3:
A single 2x0,5mm
2
cable can be used instead of two 4x0,5mm
2
cables.
Note 4:
Please refer to Chapter “7.3.2 STOP Input” in situations where there is more than one edge, for information about the type of connec-
tion recommended by the manufacturer.
Note 5:
special devices which enable connection even when the leaf is moving must be used to connect movable edges to sliding leaves.
Connection
Cable type
Maximum length allowed
A:
Power line
1 3x1,5mm
2
cable
30m (note 1)
B:
Flashing light with aerial
1 2x0,5mm
2
cable 20m
1 RG58 type shielded cable
20m (recommended less than 5 m)
C:
Photocells
1 2x0,5mm
2
cable
30m (note 2)
D:
Key-operated selector switch
2 2x0,5mm
2
cable (note 3)
50m
E:
Fixed edges
1 2x0,5mm
2
cable (note 4)
30m
F:
Movable edges
1 2x0,5mm
2
cable (note 4)
30m (note 5)
Table 5: List of cables